Adtran SFP 100Base-TX RJ-45 100m 1442200G1 Folheto

Códigos do produto
1442200G1
Página de 2
jobAid
1
D
ESCRIPTION
The ADTRAN 100Base‐TX, RJ‐45 Copper Small Form‐Factor 
Pluggable (SFPFC) plugs into appropriate ADTRAN Ethernet 
modules to provide a 100Base‐TX interface over an RJ‐45 type 
copper connector.
The SFPFC supports the following features:
100Base‐TX compliant
Auto‐Negotiation: full‐duplex or half‐duplex
Uses Category 5 or 5e shielded twisted‐pair cable (or better)
NOTICE
The SFPFC may not operate in all SFP‐based Ethernet modules. To
determine if the SFPFC is appropriate for use in a particular
module, refer to the documentation for that module, or contact
ADTRAN Customer Support.
NOTE
The SFPFC does not support Auto‐MDIX.
Operational Specifications
Max. operational distance (over Cat 5 cable): 100 meters
Operates in modules supporting the following voltage inputs:
±24 VDC Nominal (±20.0 VDC to ±28.3 VDC)
–48 VDC Nominal (–40.0 VDC to –56.7 VDC)
Extended environmental support:
Operational temperature range: –40°C to +65°C
Storage temperature range: –40°C to +85°C
Relative humidity to 95%, noncondensing
Operating altitude range:
–197 to +13,000 feet (–60 to +3,962 meters)
Operating ambient temperature is de‐rated 1°C/1000 feet
Small Form-Factor Pluggable, 
100Base-TX, RJ-45 Copper
I
NSTALLATION
Prior to installation, inspect the SFPFC. If damage has occurred 
during shipping, file a claim with the carrier, and then contact 
ADTRAN Customer Support. Refer to 
To install the SFPFC into an appropriate module, complete the 
following steps:
1.
If present, remove the safety cap from the connector of the 
SFPFC.
2.
Insert the SFPFC into the SFP cage of the host module, with the 
removal latch facing outward. Slide the SFPFC all the way into 
the cage.
3.
Firmly squeeze the receptacle and SFPFC together, to ensure a 
proper connection.
NOTE
The latch on the SFP is for removal only.
4.
Continue the installation and turn‐up of the host module using 
the instructions in the Job Aid provided with that module, or 
using the Installation and Maintenance Guide (I&M) available 
online at 
www.adtran.com
.
P
ROVISIONING
The SFPFC is not directly provisionable. To provision the SFPFC, 
access the menu system of the host module.
Refer to the “Provisioning” section of the Job Aid or I&M provided 
with the host module for provisioning details.
M
AINTENANCE
The SFPFC does not require routine hardware maintenance for 
normal operation. ADTRAN does not recommend that repairs be 
attempted in the field. Repair services may be obtained by 
returning the defective unit to ADTRAN. Field support for 
software is provided through upgrade facilities. Refer to 
 for further information.
CLEI: SOUIA84L_ _
Product P/N: 1442200G1
Issue Date: April 2010
Document P/N: 61442200G1-22A