Adtran SFP 100Base-TX RJ-45 100m 1442200G1 Folheto
Códigos do produto
1442200G1
jobAid
1
D
ESCRIPTION
The ADTRAN 100Base‐TX, RJ‐45 Copper Small Form‐Factor
Pluggable (SFPFC) plugs into appropriate ADTRAN Ethernet
modules to provide a 100Base‐TX interface over an RJ‐45 type
copper connector.
Pluggable (SFPFC) plugs into appropriate ADTRAN Ethernet
modules to provide a 100Base‐TX interface over an RJ‐45 type
copper connector.
The SFPFC supports the following features:
♦
100Base‐TX compliant
♦
Auto‐Negotiation: full‐duplex or half‐duplex
♦
Uses Category 5 or 5e shielded twisted‐pair cable (or better)
NOTICE
The SFPFC may not operate in all SFP‐based Ethernet modules. To
determine if the SFPFC is appropriate for use in a particular
module, refer to the documentation for that module, or contact
ADTRAN Customer Support.
determine if the SFPFC is appropriate for use in a particular
module, refer to the documentation for that module, or contact
ADTRAN Customer Support.
NOTE
The SFPFC does not support Auto‐MDIX.
Operational Specifications
♦
Max. operational distance (over Cat 5 cable): 100 meters
♦
Operates in modules supporting the following voltage inputs:
◊
±24 VDC Nominal (±20.0 VDC to ±28.3 VDC)
◊
–48 VDC Nominal (–40.0 VDC to –56.7 VDC)
♦
Extended environmental support:
◊
Operational temperature range: –40°C to +65°C
◊
Storage temperature range: –40°C to +85°C
◊
Relative humidity to 95%, noncondensing
♦
Operating altitude range:
◊
–197 to +13,000 feet (–60 to +3,962 meters)
◊
Operating ambient temperature is de‐rated 1°C/1000 feet
Small Form-Factor Pluggable,
100Base-TX, RJ-45 Copper
I
NSTALLATION
Prior to installation, inspect the SFPFC. If damage has occurred
during shipping, file a claim with the carrier, and then contact
ADTRAN Customer Support. Refer to
during shipping, file a claim with the carrier, and then contact
ADTRAN Customer Support. Refer to
To install the SFPFC into an appropriate module, complete the
following steps:
following steps:
1.
If present, remove the safety cap from the connector of the
SFPFC.
SFPFC.
2.
Insert the SFPFC into the SFP cage of the host module, with the
removal latch facing outward. Slide the SFPFC all the way into
the cage.
removal latch facing outward. Slide the SFPFC all the way into
the cage.
3.
Firmly squeeze the receptacle and SFPFC together, to ensure a
proper connection.
proper connection.
NOTE
The latch on the SFP is for removal only.
4.
Continue the installation and turn‐up of the host module using
the instructions in the Job Aid provided with that module, or
using the Installation and Maintenance Guide (I&M) available
online at
the instructions in the Job Aid provided with that module, or
using the Installation and Maintenance Guide (I&M) available
online at
www.adtran.com
.
P
ROVISIONING
The SFPFC is not directly provisionable. To provision the SFPFC,
access the menu system of the host module.
access the menu system of the host module.
Refer to the “Provisioning” section of the Job Aid or I&M provided
with the host module for provisioning details.
with the host module for provisioning details.
M
AINTENANCE
The SFPFC does not require routine hardware maintenance for
normal operation. ADTRAN does not recommend that repairs be
attempted in the field. Repair services may be obtained by
returning the defective unit to ADTRAN. Field support for
software is provided through upgrade facilities. Refer to
normal operation. ADTRAN does not recommend that repairs be
attempted in the field. Repair services may be obtained by
returning the defective unit to ADTRAN. Field support for
software is provided through upgrade facilities. Refer to
CLEI: SOUIA84L_ _
Product P/N: 1442200G1
Product P/N: 1442200G1
Issue Date: April 2010
Document P/N: 61442200G1-22A