C A U T I O N 
C A U T I O N ! 
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
This device complies with Part 15 of the FCC rules. Operation is 
subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including 
interference that may cause undesired operation.
Changes or modifications not expressly approved by ADTRAN 
could void the userʹs authority to operate this equipment.
Warranty
: ADTRAN will replace or repair this product within the warranty period if it does not meet its 
published specifications or fails while in service. Warranty information can be found online at 
www.adtran.com/warranty
.
©2010 ADTRAN, Inc. All Rights Reserved.
*61442300G1-22B*
CAUTION
!
♦  
Per GR‐1089‐CORE the ADTRAN system that the SFP is being
deployed in is designed and intended for installation as part of
a Common Bonding Network (CBN). The ADTRAN system
that the SFP is being deployed in is not designed nor intended
for installation as part of an Isolated Bonding Network (IBN).
♦  
Per GR‐1089‐CORE Section 9, the SFP does not have an internal
DC connection between battery return and frame ground. The
SFP can be installed in a DC‐I (isolated) or DC‐C (common)
configuration. For installations where other cards or the host
system have internal connections between battery return and
frame ground, the system would be intended for deployment
only in a DC‐C configuration.
♦  
The ADTRAN system chassis frame ground terminal must be
connected to a reliable earth ground to ensure that the metal
enclosure of the SFP is properly grounded via the backplane
connector.
NOTE
The  SFP  is  designed  for  deployment  in  GR‐3108‐CORE
environmental class 1 and 2, as defined in GR‐3108‐CORE, Issues
2.
The SFP is designed to meet the following environmental classes:
ETSI EN 300 019‐1‐1 “Classification of environmental 
conditions; Storage,” Class 1.2
ETSI EN 300 019‐1‐2 “Classification of environmental 
conditions; Transportation,” Class 2.3
ETSI EN 300 019‐1‐3 “Classification of environmental 
conditions; Stationary use at weather‐protected locations,” 
Class 3.3
The equipment is designed to function without degradation 
during exposure to all test severities per Class 3.3.