3.  Chassis Cooling 
3.1 
Fan Configuration 
The cooling sub-system of the Intel
®
 Entry Server Chassis SC5299-E consists of one system 
fan and one power supply fan (the SC5299WS configuration has an additional 92-mm drive bay 
fan). The 4-wire 120mm x 38mm fan provides cooling at the rear of the chassis by drawing fresh 
air into the chassis from the front and exhausting warm air out the system. This fan is PWM 
controlled. The server board monitors several temperature sensors and adjusts the duty cycle of 
the PWM signal to drive the fan at the appropriate speed. The 92-mm drive bay fan for the 
SC5299WS configuration and the optional hot-swap drive bay kit provides additional cooling to 
the drive bay by drawing fresh air from the front of the chassis through the drive bay and 
exhausting it into the PCI bay area. 
Removal and insertion of the 120-mm or 92-mm fan can be done without tools. The power 
supply fan assists in drawing air through the peripheral bay area, through the power supply and 
exhausting it out the rear of the chassis. All versions of the Intel
®
 Entry Server Chassis SC5299-
E are optimized for server and workstation boards that have an active CPU heatsink solution.  
If an optional hot-swap drive bay is installed, a 4-wire 92-mm fan is included with the mounting 
bracket kit for installation onto the drive bay. This fan has a PWM circuit that allows the server 
board to control the fan speed based on sensor readings of ambient temperature. 
In addition to these pre-installed fans, locations for three additional fans are provided for 
customized configurations. Intel does not provide order part numbers for these customizable fan 
options. A 120-mm fan can be mounted to the chassis behind the PCI card guide and provide 
additional cooling to the PCI card area; two 80-mm fans can be mounted at the front of the 
chassis to the right of the hard drive bay opening to provide more cooling. 
The front panel of the Intel
®
 Entry Server Chassis SC5299-E provides a LM30 temperature 
sensor for SIO control. Server boards that support SIO control may use the LM30 sensor to 
adjust fan speeds according to air intake temperatures. Refer to the server board 
documentation for configuring use of the front panel sensor.  
3.2 
Server Board Fan Control 
The fans provided in the Intel
®
 Entry Server Chassis SC5299-E contain a tachometer signal that 
can be monitored by the server management subsystem for the Intel
®
 Server Boards 
S5000XVN and S5000VSA. See the specific server board Technical Product Specification for 
details on how this feature works.