Intel SC5299UP SC5299UPNA Manual Do Utilizador

Códigos do produto
SC5299UPNA
Página de 154
Intel
®
 Entry Server Chassis SC5299-E TPS 
Power Sub-system 
Revision 3.1 
 
 
Intel order number D37594-005 
49
 
2.3.2.7.1 
Electrostatic Discharge Susceptibility 
The power supply complies with the limits defined in EN 55024: 1998 using the IEC 61000-4-2:1995 test 
standard and performance criteria B defined in Annex B of CISPR 24. 
 
2.3.2.7.2 
Fast Transient/Burst 
The power supply complies with the limits defined in EN55024: 1998 using the IEC 61000-4-4:1995 test 
standard and performance criteria B defined in Annex B of CISPR 24. 
 
2.3.2.7.3 
Radiated Immunity 
The power supply complies with the limits defined in EN55024: 1998 using the IEC 61000-4-
3:1995 test standard and performance criteria A defined in Annex B of CISPR 24. 
2.3.2.7.4 
Surge Immunity 
The power supply has been tested with the system for immunity to AC Ringwave and AC 
Unidirectional wave, both up to 2kV, per EN 55024:1998, EN 61000-4-5:1995 and ANSI C62.45: 
1992. 
The pass criteria included: No unsafe operation allowed under any condition; all power supply 
output voltage levels remain within proper spec levels; no change in operating state or loss of 
data during and after the test profile; no component damage under any condition. 
The power supply complies with the limits defined in EN55024: 1998 using the IEC 61000-4-
5:1995 test standard and performance criteria B defined in Annex B of CISPR 24.  
2.3.2.8 
AC Line Dropout/Holdup 
Below are the AC dropout requirements. 
Table 56. Holdup Requirements 
Loading 
Holdup Time 
100% 12 
msec 
60% 20 
msec 
 
An AC line dropout is defined to be when the AC input drops to 0VAC at any phase of the AC 
line for any length of time. During an AC dropout condition, the power supply meets dynamic 
voltage regulation requirements. An AC line dropout of any duration will not cause tripping of 
control signals or protection circuits. If the AC dropout lasts longer than the hold up time, the 
power supply recovers and meets all turn on requirements. The power supply meets the AC 
dropout requirement over rated AC voltages and frequencies. A dropout of the AC line for any 
duration will not cause damage to the power supply.