7. 3 Synchro. Scan Operation
The shutter speed can be set by the horizontal scanning period (1H) or by the frame.
( 1 )   Setting by 1H
1H/525H ~ 524H/525H stands for the setting by the 1H and the shutter speed can be set by the 1H (31.8 
µ
s).
When operating Partial Scannig, the number’s listed below can be used for setting.
Partial scanning OFF
1H/525H ~ 524H/525H
90fps, E90fps
1H/348H ~ 347H/348H
115fps, E115fps
1H/272H ~ 271H/272H
120fps, E120fps
1H/262H ~ 261H/262H
160fps, E160fps
1H/197H ~ 196H/197H
180fps, E180fps
1H/175H ~ 174H/175H
240fps, E240fps
1H/131H ~ 130H/131H
( 2 )   Setting by the frame
2FRM to 512FRM stand for the setting (long period exposure) by the frame.
The video signal stored during the frame period set is output as 1 frame video image at a frame interval
specified.
(4FRM setting)
n n+1 
RGB data 
(video interval image)
(Internal VD) 
FVAL
LVAL,
DAVL
( 7 )   Returning to factory settings
All the settings can be returned to the factory default status (preset status).
(1) If characters are displayed on the screen, press the [DISP] button to disable the character display.
(2) Push [MENU DOWN] and [DATA DOWN] buttons simultaneously for approx. 1 second.
(3) The preset operation starts. When the preset operation finishes, the character PRESET OK is displayed
for approx. 1 second.