To avoid this, MSTP provides root protect function. Ports with this function enabled can only be set 
as designated ports in all spanning tree instances. When a port of this type receives BDPU 
packets with higher priority, it transits its state to blocking state and stops forwarding packets (as if 
it is disconnected from the link). The port resumes the normal state if it does not receive any 
configuration BPDU packets with higher priorities for a period of two times of forward delay. 
 
TC Protect 
A switch removes MAC address entries upon receiving TC-BPDU packets. If a user maliciously 
sends a large amount of TC-BPDU packets to a switch in a short period, the switch will be busy 
with removing MAC address entries, which may decrease the performance and stability of the 
network. 
To prevent the switch from frequently removing MAC address entries, you can enable the TC 
protect function on the switch. With TC protect function enabled, if the account number of the 
received TC-BPDUs exceeds the maximum number you set in the TC threshold field, the switch 
will not performs the removing operation in the TC protect cycle. Such a mechanism prevents the 
switch from frequently removing MAC address entries. 
 
BPDU Protect 
Ports of the switch directly connected to PCs or servers are configured as edge ports to rapidly 
transit their states. When these ports receive BPDUs, the system automatically configures these 
ports as non-edge ports and regenerates spanning trees, which may cause network topology jitter. 
Normally these ports do not receive BPDUs, but if a user maliciously attacks the switch by sending 
BPDUs, network topology jitter occurs. 
To prevent this attack, MSTP provides BPDU protect function. With this function enabled on the 
switch, the switch shuts down the edge ports that receive BPDUs and reports these cases to the 
administrator. If a port is shut down, only the administrator can restore it. 
 
BPDU Filter 
BPDU filter function is to prevent BPDUs flood in the STP network. If a switch receives malicious 
BPDUs, it forwards these BPDUs to the other switched in the network, which may result in 
spanning trees being continuously regenerated. In this case, the switch occupying too much CPU 
or the protocol status of BPDUs is wrong. 
With BPDU filter function enabled, a port does not receive or forward BPDUs, but it sends out its 
own BPDUs. Such a mechanism prevents the switch from being attacked by BPDUs so as to 
guarantee generation the spanning trees correct. 
Choose the menu Spanning Tree→STP Security→Port Protect to load the following page. 