Grounding the Industrial PoE Switch 
  
  CAUTION 
Be sure to disconnect the Industrial PoE Switch from the DC power source before 
installing and wiring the device.  
  
Wiring 
considerations 
The following wiring considerations are recommended: 
•  Signal lines must not be directly connected to outdoor wiring. 
•  Use separate paths or conduits to route wiring for power and device data cables.  To avoid 
interference, wires with different signal characteristics route separately.  If power wiring and 
device data cables must cross make sure that the wires are perpendicular at the 
intersection point.  
•  Use the type of signal transmitted through a wire to determine which wires should be kept 
separate.  The rule of thumb is wiring that shares similar electrical characteristics can be 
bundled together.   
•  Keep input and output wiring separated. 
  
  CAUTION 
The Industrial PoE Switch is intended to be grounded to a well-grounded mounting 
surface such as a metal plate.  Install the grounding wire prior to connecting any other 
device to the Industrial PoE Switch.  
  
Industrial PoE 
Switch 
grounding 
Grounding the Industrial PoE Switch helps limit the effects of noise due to electromagnetic 
interference (EMI) via proper grounding.  Always run the ground connection from the ground 
screw to a grounding surface before connecting the Industrial PoE Switch to a DC power 
source. See Figure 7. 
 
 