Eaton T2235-F3-CFB15L Folheto
UNITED STATES
8609 Six Forks Road
Raleigh, NC 27615 U.S.A.
Toll Free: 1.800.356.5794
www.epdu.com
CANADA
Ontario: 416.798.0112
Toll free: 1.800.461.9166
LATIN AMERICA
South Cone: 54.11.4124.4000
Brazil: 55.11.3616.8500
Andean & Caribbean:
1.949.452.9610
Mexico & Central America:
52.55.9000.5252
EUROpE/MIDDLE EAST/AFRICA
Denmark: 45.3686.7910
Finland: 358.94.52.661
France: 33.1.6012.7400
Germany: 49.0.7841.604.0
Italy: 39.02.66.04.05.40
Norway: 47.23.03.65.50
portugal: 55.11.3616.8500
Sweden: 46.8.598.940.00
United Kingdom: 44.1753.608.700
ASIA pACIFIC
Australia: 61.2.9693.9366
New Zealand: 64.0.3.343.3314
China: 86.21.6361.5599
HK/Korea/Taiwan: 852.2745.6682
India: 91.11.4223.2300
Singapore/SEA: 65.6825.1668
Eaton and PowerChain Management are
registered trademarks of Eaton Corporation.
All other trademarks are property of their
respective owners.
©2010 Eaton Corporation
All Rights Reserved
printed in USA
pDU23FXA_1010
December 2010
Dual Power Input
• Power cables with plugs are
attached to unit through the rear
panel cable grip
panel cable grip
• -AB version has C20 inlets
- Cables must be ordered
- Cables must be ordered
separately
Overload Circuit Protection
• (Optional) Electromagnetic
circuitbreakers with long time
delay curve
delay curve
• Circuit breaker trip guards are
provided
• C1, C2, F3, F4 require circuit breakers
for branch circuit protection to meet
NEC and UL requirements
NEC and UL requirements
Voltage Range Selection
• The “AB” International (IEC) version
allows for all three voltage ranges
120V, 208V, or 240V
120V, 208V, or 240V
• Front panel switch to set the drop
out and pull in range to the desired
voltages see chart above
voltages see chart above
• This allows this one version to be
specified for worldwide usage
Spike/Surge Suppression (TVSS)
• Transient voltage surge suppression
prevents damage due to voltage
fluctuations
fluctuations
• Metal Oxide Varistors (MOVs) are
utilized Line to Line (or neutral)
• Please refer to the table on the
right for MOV specifications
Auto Transfer Switch
• Firm drop out points allow a transfer
before an under-voltage will affect
equipment operation
equipment operation
• Transfer ranges (Voltage):
• Sources do NOT need to be
phase synchronized for T2235 part
numbers only
numbers only
• Source transfer time of less than
30ms (clean sine wave to clean sine
wave)
wave)
• Front panel LED’s indicate which
sources are available and selected
at the output
at the output
Nominal
Drop Out pull In
120V
90V
103V
208V
182V
195V
240V
197V
210V
Part Number
Style Number
Input Plug
Cord (ft.)
Receptacles
Dimensions
(W x H x D, in)
PWATSL520004
T2235-A2-NNB09L
(2) L5-20P
9
(8) 5-20R
1.75 x 19 x 7
PWATSL530005
T2235-C2-CNB09L
(2) L5-30P
9
(8) 5-20R
1.75 x 19 x 9
PWATSL530007
T2235-3369
(2) L5-30P
9
(1) L5-30R
1.75 x 19 x 7
PWATSL630006
T2235-F3-CNB09L
(2) L6-30P
9
(12) C13
1.75 x 19 x 9
PWATSL630008
T2235-3358
(2) L6-30P
9
(1) L6-30R
1.75 x 19 x 7
PWATSS515002
T2235-A1-NNB09S
(2) 5-15P
9
(8) 5-15R
1.75 x 19 x 7
PWATSS520003
T2235-A2-NNB09S
(2) 5-20P
9
(8) 5-20R
1.75 x 19 x 7
PWATSSC20001
T2235-AB-NNBC20
(2) C20
N/A
(8) C13, (1) C19
1.75 x 19 x 7
These part numbers represent our TopSelling ATS units. please visit www.epdu.com for other ATS configurations.
TVSS (Transient Voltage Surge Suppression)
MOV SPECIFICATIONS
Continuous AC Voltage
150VAC
270VAC
320VAC
Continuous DC Voltage
200VDC
360VDC
420VDC
Max. DC Leakage
200μA
200μA
200μA
Low Varistor Voltage Limit
212VDC
389VDC
462VDC
High Varistor Voltage Limit
243VDC
453VDC
540VDC
Nominal Varistor Voltage
236VDC
424VDC
503VDC
Current For Varistor Voltage
1mA
1mA
1mA
Max. Clamp Voltage 8x20μs
360V
680V
810V
Max. Clamp Voltage Test Current
100A
100A
100A
Peak Current Rating (1 Pulse)
12000A
10000A
10000A
Peak Current Rating (2 Pulse)
9000A
6500A
6500A
Energy Rating (10x1000μs)
170J
325J
385J
Energy Rating (8x20μs)
170J
325J
385J
Capacitance
1700pF
970pF
820pF
Impulse Response Time
50ns
50ns
50ns