Adaptec AFM-700 2275400-R Ficha De Dados

Códigos do produto
2275400-R
Página de 2
AFM-700    
DATA SHEET
PMC-Sierra, Inc.
1380 Bordeaux Dr. 
Sunnyvale, CA 94089  USA   
Tel: +1 (408) 239-8000
© Copyright PMC-Sierra, Inc. 2012. All rights reserved. PMC, PMC-SIERRA and Adaptec are registered trademarks of PMC-Sierra, Inc. “Adaptec by PMC” is a trademark of PMC-Sierra, Inc. 
Other product and company names mentioned herein may be trademarks of their respective owners. For a complete list of PMC-Sierra trademarks, see www.pmc-sierra.com/legal.
DS_AFM700_091912_US      Information subject to change without notice.
World Wide Web: www.adaptec.com
Pre-Sales Support:
  US and Canada: 1 (800) 442-7274 or (408) 957-7274 or adaptecsales@pmc-sierra.com
 
UK: 
+44 1276 854 528 or uk_sales@pmc-sierra.com
 
Australia: 
+61-2-90116787
 
Singapore: 
+65-92351044
Why to buy
The Adaptec Flash Module 700 (AFM-700) provides Zero-Maintenance Cache Protection (ZMCP) for
Adaptec Series 7 and Series 7Q RAID adapters to protect data in the controller cache without incurring  
monitoring, maintenance, replacement, or disposal costs.
Customer Needs 
Solutions that require advanced protection of data and reduced Total Cost of Ownership (TCO).
Compatible Products
•  
Adaptec RAID 72405
•  
Adaptec RAID 71685
•  
Adaptec RAID 71605
•  
Adaptec RAID 7805
•  
Adaptec RAID 71605Q (included)
•  
Adaptec RAID 7805Q (included)
Operating Temperature 
0°C to 50°C (with 200 LFM airflow)
Operating Current
ASR-7805/7805Q: 0.1A@3.3V and 1.5A@12V
ASR-71605/71605Q: 0.1A@3.3V and 1.6A@12V
ASR-71605E: 0.1A@3.3V and 1.5A@12V
ASR-71685/72405: 0.1A@3.3V and 1.8A@12V measured on PCIe Gen3 systems with 6G drives
Regulatory Certification 
CE, FCC, UL, C-tick, VCCI, KCC
Environmental Compliance 
RoHS
Typical Lifespan
5 years at 50°C
Warranty 
3 years
Part Number
2275400-R
BBUs vs. ZMCP: Maintenance Requirements
Adaptec Flash Module 700 (AFM-700)
Lithium-ion BBUs
Adaptec by PMC ZMCP
Batteries must be “conditioned” during initial deployment, adding custom steps and several hours to 
the deployment process
No action required
Battery performance must be continually monitored so that failing batteries can be replaced
No action required
A failed battery must be replaced within 72 hours, and sometimes less
No action required
Batteries must be replaced on a regular maintenance cycle, so replacement batteries must be kept 
available at each location and maintenance staff must be on-site or on-call
No action required
Replacement batteries “age” even when on the shelf, so a continual purchasing process must be 
developed and implemented
No action required
Lithium-ion batteries must be properly disposed. A process to dispose of the hazardous material must 
be created, staffed, and funded
No action required