Fujitsu TX200 S7 + Windows Server 2012 Standard 2CPU & 2VM VFY:T2007SC020IN + S26361-F2567-D420 Ficha De Dados
Códigos do produto
VFY:T2007SC020IN + S26361-F2567-D420
Data Sheet
Fujitsu PRIMERGY TX200 S7 Server
Page 3 / 10
www.fujitsu.com/fts
Technical details
PRIMERGY TX200 S7
Housing types
Tower / Rack
Tower / Rack
Storage drive architecture
3.5-inch
2.5-inch
Power supply
Standard / Hot-plug
Standard / Hot-plug
Mainboard
Mainboard type
D 3099
Chipset
Intel® C602
Processor quantity and type
1 - 2 x Intel® Xeon® processor E5-2400 product family
Processor
Intel® Xeon® processor E5-2403
(4C/4T, 1.80 GHz, TLC: 10 MB, Turbo: No, 6.4 GT/s, Mem bus: 1066 MHz, 80 W)
Intel® Xeon® processor E5-2407
(4C/4T, 2.20 GHz, TLC: 10 MB, Turbo: No, 6.4 GT/s, Mem bus: 1066 MHz, 80 W)
Intel® Xeon® processor E5-2420
(6C/12T, 1.90 GHz, TLC: 15 MB, Turbo: Yes, 7.2 GT/s , Mem bus: 1333 MHz, 95 W)
Intel® Xeon® processor E5-2430
(6C/12T, 2.20 GHz, TLC: 15 MB, Turbo: Yes, 7.2 GT/s , Mem bus: 1333 MHz, 95 W)
Intel® Xeon® processor E5-2430L
(6C/12T, 2.00 GHz, TLC: 15 MB, Turbo: Yes, 7.2 GT/s , Mem bus: 1333 MHz, 60 W)
Intel® Xeon® processor E5-2440
(6C/12T, 2.40 GHz, TLC: 15 MB, Turbo: Yes, 7.2 GT/s , Mem bus: 1333 MHz, 95 W)
Intel® Xeon® processor E5-2450
(8C/16T, 2.10 GHz, TLC: 20 MB, Turbo: Yes, 8.0 GT/s , Mem bus: 1600 MHz, 95 W)
Intel® Xeon® processor E5-2470
(8C/16T, 2.30 GHz, TLC: 20 MB, Turbo: Yes, 8.0 GT/s , Mem bus: 1600 MHz, 95 W)
(4C/4T, 1.80 GHz, TLC: 10 MB, Turbo: No, 6.4 GT/s, Mem bus: 1066 MHz, 80 W)
Intel® Xeon® processor E5-2407
(4C/4T, 2.20 GHz, TLC: 10 MB, Turbo: No, 6.4 GT/s, Mem bus: 1066 MHz, 80 W)
Intel® Xeon® processor E5-2420
(6C/12T, 1.90 GHz, TLC: 15 MB, Turbo: Yes, 7.2 GT/s , Mem bus: 1333 MHz, 95 W)
Intel® Xeon® processor E5-2430
(6C/12T, 2.20 GHz, TLC: 15 MB, Turbo: Yes, 7.2 GT/s , Mem bus: 1333 MHz, 95 W)
Intel® Xeon® processor E5-2430L
(6C/12T, 2.00 GHz, TLC: 15 MB, Turbo: Yes, 7.2 GT/s , Mem bus: 1333 MHz, 60 W)
Intel® Xeon® processor E5-2440
(6C/12T, 2.40 GHz, TLC: 15 MB, Turbo: Yes, 7.2 GT/s , Mem bus: 1333 MHz, 95 W)
Intel® Xeon® processor E5-2450
(8C/16T, 2.10 GHz, TLC: 20 MB, Turbo: Yes, 8.0 GT/s , Mem bus: 1600 MHz, 95 W)
Intel® Xeon® processor E5-2470
(8C/16T, 2.30 GHz, TLC: 20 MB, Turbo: Yes, 8.0 GT/s , Mem bus: 1600 MHz, 95 W)
Memory slots
12 (6 DIMMs per CPU, 3 channels with 2 slots per channel)
Memory slot type
DIMM (DDR3)
Memory capacity (min. - max.)
2 GB - 192 GB
Memory protection
Advanced ECC
Memory Scrubbing
SDDC (Chipkill™)
Hot-spare memory support
Memory Mirroring support
Memory Scrubbing
SDDC (Chipkill™)
Hot-spare memory support
Memory Mirroring support
Memory notes
max.192 GB registered; min. 2 GB unbuffered; Memory Mirroring with identical modules in both channel pairs of a
bank (2 modules per bank). Rank sparing with identical modules within the same channel. Performance Mode with
identical modules in all channels of each bank per CPU.
bank (2 modules per bank). Rank sparing with identical modules within the same channel. Performance Mode with
identical modules in all channels of each bank per CPU.
Memory options
4 GB (1 module(s) 4 GB) DDR3 LV, registered, ECC, 1600 MHz, PC3-12800, DIMM
8 GB (1 module(s) 8 GB) DDR3 LV, registered, ECC, 1600 MHz, PC3-12800, DIMM
16 GB (1 module(s) 16 GB) DDR3 LV, registered, ECC, 1600 MHz, PC3-12800, DIMM
8 GB (1 module(s) 8 GB) DDR3 LV, registered, ECC, 1600 MHz, PC3-12800, DIMM
16 GB (1 module(s) 16 GB) DDR3 LV, registered, ECC, 1600 MHz, PC3-12800, DIMM
Memory options
2 GB (1 module(s) 2 GB) DDR3 LV, unbuffered, ECC, 1600 MHz, PC3-12800, DIMM
4 GB (1 module(s) 4 GB) DDR3 LV, unbuffered, ECC, 1600 MHz, PC3-12800, DIMM
4 GB (1 module(s) 4 GB) DDR3 LV, unbuffered, ECC, 1600 MHz, PC3-12800, DIMM
Interfaces
USB ports
9 x USB 2.0 (2 x front USB, 4 x rear USB 3 x internal for backup, UFM and internal USB)
Graphics (15-pin)
1 x VGA
Serial 1 (9-pin)
1 x serial RS-232-C (9 pin), usable for iRMC S3 or system or common use
LAN / Ethernet (RJ-45)
2 x Gbit/s Ethernet (Intel Hartwell)
Service LAN (RJ45)
1 x dedicated management LAN port for iRMC S3 (10/100/1000 Mbit/s)
Service LAN traffic can be switched to shared onboard Gbit LAN port