8068ch13-Maintenance and Troubleshooting.fm
Draft Document for Review January 29, 2013 12:52 pm
552
IBM Flex System V7000 Storage Node Introduction and Implementation Guide
problem. In all these cases the management GUI recommended action is the correct starting
point.
point.
For problem that you might experience, that is not resolved by using the management GUI. In
those situations, review the symptoms and follow the actions that are provided here. You may
be directed to the IBM Flex System V7000 Service Assistant GUI or to Flex System chassis
management devices.
those situations, review the symptoms and follow the actions that are provided here. You may
be directed to the IBM Flex System V7000 Service Assistant GUI or to Flex System chassis
management devices.
It is highly recommended that you set up CLI access to the control enclosure after initial
configuration is complete, this allows you to run necessary CLI commands when you cannot
start the management GUI or the node canisters in the control enclosure are unable to run
the system software.
configuration is complete, this allows you to run necessary CLI commands when you cannot
start the management GUI or the node canisters in the control enclosure are unable to run
the system software.
13.8.3 Removing and replacing parts for troubleshooting and resolving
problems
problems
You can remove and replace customer replaceable units (CRUs) from the control enclosure or
the expansion enclosure.
the expansion enclosure.
Even though many of these procedures are hot-swappable, they are intended to be used only
when your system is not up and running and performing I/O operations. If your system is
powered on and performing I/O operations, go to the management GUI and follow the fix
procedures. Performing the replacement actions without the assistance of the fix procedures
can result in loss of data or loss of access to data.
when your system is not up and running and performing I/O operations. If your system is
powered on and performing I/O operations, go to the management GUI and follow the fix
procedures. Performing the replacement actions without the assistance of the fix procedures
can result in loss of data or loss of access to data.
Each replaceable unit has its own removal procedure. Sometimes you can find that a step
within a procedure might refer you to a different remove and replace procedure. Complete the
new procedure before you continue with the first procedure that you started.
within a procedure might refer you to a different remove and replace procedure. Complete the
new procedure before you continue with the first procedure that you started.
13.8.4 Event reporting
Events that are detected are saved in an event log. As soon as an entry is made in this event
log, the condition is analyzed. If any service activity is required, a notification is sent.
log, the condition is analyzed. If any service activity is required, a notification is sent.
The following methods are used to notify you and the IBM Support Center of a new event:
1. If you enabled Simple Network Management Protocol (SNMP), an SNMP trap is sent to an
SNMP manager that is configured by the customer.
2. If enabled, log messages can be forwarded from a sender to a receiver on an IP network
by using the Syslog protocol.
Attention: After you have created your clustered system, remove hardware components
only when directed to do so by the fix procedures. Failure to follow the procedures can
result in loss of access to data or loss of data. Follow the fix procedures when servicing a
control enclosure.
only when directed to do so by the fix procedures. Failure to follow the procedures can
result in loss of access to data or loss of data. Follow the fix procedures when servicing a
control enclosure.
Attention: If your system is powered on and performing I/O operations, go to the
management GUI and follow the fix procedures. Removing a node without the assistance
of the fix procedures can result in loss of data or access to data
management GUI and follow the fix procedures. Removing a node without the assistance
of the fix procedures can result in loss of data or access to data
Note: Remove or replace CRU parts only when you are directed to do so. The field
replaceable units (FRUs) must be installed only by trained service technicians.
replaceable units (FRUs) must be installed only by trained service technicians.