Technical Data
Connection specification for a/b subscriber
Connection specifications for DECT subscriber
Connection specification for a/b subscriber
a/b Interface
Feed voltage: –40 V
Feed current: approx. 20 mA
Permissible line resistance: 550 Ohm (incl. device)
Ranges for 2 x 130 Ohm line
resistance:
Installation cable 0.4 mm
2
(J-Y(St)Y2x2x0.4): approx. 1350 m
Installation cable 0.6 mm
2
(J-Y(St)Y2x2x0.6): approx. 2900 m
Connection specifications for DECT subscriber
UPD Interface (4-wire):
Feed voltage: –40 V
Transmission rate: 4xB per 64 kBit/s and 2xD per 16 kBit/s
Bit rate on lines: 384 kBit/s in send and receive directions
Ranges with 4 x 100 Ohm, installation cable 0.6 mm
2
J-Y(St)Y2 x 2 x 0.6)
Point to point connection: approx. 1,000 m