Superior Essex 01-100-38 Folheto
F-4
Premises
Co
PP
er
Premises
Fiber
o
sP
Fiber
o
sP
Com
Po
Po
site
Centr
al
oFF
iC
oFF
iC
e
Co
PP
er
rDUP
/r
/r
U
s o
sP
Co
PP
er
bell
o
o
sP
Co
PP
er
o
sP
Co
PP
er
Wire
Wire
Cana
D
D
ian
o
o
sP
Co
PP
er
te
Chni
Cal
in
Cal
in
Fo
Rev 1/12 Ed 11.0
Toll Free
800.551.8948 | Fax 770.657.6807 |
Specifications
Conductor
Solid annealed copper
Insulation
Solid polyolefin; color coded in accordance with
industry standards
Twisted Pairs
Individual insulated conductors are twisted into pairs with
varying lay lengths; specific color combinations provide
pair identification
≤ 25-Pair Core
Pairs are assembled into a cylindrical core
> 25-Pair Core
Cables larger than 25-pair are assembled into units,
which are then used to assemble the core; units
are identifiable using color-coded binders
Core Wrap
Non-hygroscopic, dielectric tape
Shield
Corrugated, copolymer coated, 8 mil aluminum tape
applied longitudinally with an overlap
Support Member
0.25 inch, 7-strand Extra High Strength (EHS) galvanized
steel messenger serves as support member and
integral part of the sheath; messenger is flooded
Jacket
Black, polyethylene
Jacket Marking
Identifying information includes a telephone handset,
cable code, pair count, AWG, date of manufacture
and sequential length markings at 2 foot intervals
Standards Compliance
ANSI/ICEA S-85-625-2007
Formerly PE-38
RoHS-compliant
Electrical Specifications
Number of Pairs
Average Mutual
Capacitance @ 1000 Hz
nF/mile (nF/km)
Capacitance Unbalance
Pair to Pair @ 1 kHz
Capacitance Unbalance
Pair to Ground @ 1 kHz
Maximum Individual
pF @ 1 kft (pF @ 1 km)
Maximum RMS
pF @ 1 kft (pF @ 1 km)
Maximum Individual
pF @ 1 kft (pF @ 1 km)
Maximum Average
pF @ 1 kft (pF @ 1 km)
12 or less
83 ± 7 (52 ± 4)
80 (145)
-
800 (2,625)
-
Over 12
83 ± 4 (52 ± 2)
80 (145)
25 (45)
800 (2,625)
175 (574)
Conductor Size
AWG (mm)
Minimum Insulation
Resistance @ 68°F (20°C)
gigohm-mile (gigohm-km)
Maximum Average
Attenuation*
772 kHz @ 68°F (20°C)
dB/kft (dB/km)
Maximum Conductor
Resistance @ 68°F (20°C)
Ohms/sheath
mile (km)
DC Resistance Unbalance
Maximum %
Dielectric Strength
DC Potential – Volts
Average
Individual
Pair
Conductor
to Conductor
Conductor
to Shield
19 (0.90)
1.0 (1.6)
3.3 (10.8)
45.0 (28.0)
1.5
5.0
5,000
10,000
22 (0.64)
1.0 (1.6)
4.7 (15.4)
91.0 (56.5)
1.5
5.0
4,000
10,000
24 (0.51)
1.0 (1.6)
5.9 (19.4)
144.0 (89.5)
1.5
5.0
3,000
10,000
*For cables with 12-pair or less, the maximum average attenuation may be increased by 10% over the values shown.
Minimum Near End Crosstalk (NEXT)
@ 772 kHz
PSWUNEXT Mean (dB)
47
PSWUNEXT Worst Pair (dB)
42
Minimum Far End Crosstalk (FEXT)
@ 772 kHz
Conductor Size (AWG)
19
22
24
PSELFEXT Mean (dB/kft)
51
49
49
PSELFEXT Worst Pair (dB/kft)
45
43
43
sealPiC®–84
Product Description
SEALPIC®-84 Cables have an air core design and are suited for aerial
installations. The core and support member (messenger) lay parallel to
each other forming a cross-sectional “figure 8.” The support messenger
is an integral part of the cable sheath, yet readily available for gripping,
pulling and tensioning.
installations. The core and support member (messenger) lay parallel to
each other forming a cross-sectional “figure 8.” The support messenger
is an integral part of the cable sheath, yet readily available for gripping,
pulling and tensioning.
Applications
• Aerial
Features
Benefits
• Twisted into pairs with varying
lay lengths
• Minimizes crosstalk
• Core wrap
• Provides thermal protection
• Fully flooded steel
support member
• Inhibits corrosion
• Black, polyethylene jacket
• Provides a tough, protective
covering designed to withstand
exposure to direct sunlight,
atmospheric temperature
changes and stresses expected
in standard installations