Cisco OC-192/STM-64 Optics Card 15454-OC192SR1310= Ficha De Dados
Códigos do produto
15454-OC192SR1310=
Data Sheet
All contents are Copyright © 1992–2006 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information.
Page 10 of 11
Specification
SR/IO 1310-nm
IR/SH 1550-nm LR/LH 1550-nm
LR/LH 1550-nm
(End-of-Sale
Pending)
(End-of-Sale
Pending)
LR/ELH
15xx.xx-nm
15xx.xx-nm
Chromatic
dispersion
tolerance (D
dispersion
tolerance (D
Lrmax
)
6.6 ps/nm
800 ps/nm
1600 ps/nm
1360 ps/nm
Without dispersion
compensation unit
(DCU): ±1200 ps/nm
with OSNR of 23 dB
(0.5 nm RBW)
compensation unit
(DCU): ±1200 ps/nm
with OSNR of 23 dB
(0.5 nm RBW)
With DCU:
±1000 ps/nm with
OSNR of 19 dB (0.5
nm RBW)
OSNR of 19 dB (0.5
nm RBW)
Power penalty
(P
(P
O
)
1 dB
2 dB
2 dB
4 dB (@ 80 km)
N/A
BER, minimum
(BERmin)
(BERmin)
1E-12
1E-12
1E-12
1E-12
1E-12
Maximum receiver
reflectance
reflectance
–14 dB
–27 dB
–27 dB
–27 dB
–27 dB
Optical signal-to-
noise ratio
(0.5 nm bandwidth
@ 1E-12 BER)
noise ratio
(0.5 nm bandwidth
@ 1E-12 BER)
30 dB
20 dB
20 dB
20 dB
Without DCU:
–1200 ps/nm with
OSNR of 23 dB (0.5
nm RBW)
–1200 ps/nm with
OSNR of 23 dB (0.5
nm RBW)
With DCU:
–1000 ps/nm with
OSNR of 19 dB (0.5
nm RBW)
OSNR of 19 dB (0.5
nm RBW)
Input wavelength
bandwidth (
bandwidth (
λ
c_rx
)
1290 to 1330 nm
4
1530 to
1565 nm
1565 nm
4
1290 to 1605 nm
1290 to 1605 nm
4
1529 to 1562 nm
4
Connector type
(Tx/Rx)
(Tx/Rx)
SC, duplex
SC, duplex
SC, duplex
SC, duplex
SC, duplex
Management
Card LEDs
Failure (FAIL)
Active/standby
(ACT/STBY)
(ACT/STBY)
Signal fail (SF)
Red
Green/yellow
Yellow
Red
Green/yellow
Yellow
Red
Green/yellow
Yellow
Red
Green/yellow
Yellow
Red
Green/yellow
Yellow
Power
Card power draw,
maximum
maximum
48W
48W
52W
72.2W
52W
Operating Environment
Temperature
–5 to 55ºC
(23 to 131ºF)
(23 to 131ºF)
–5 to 55ºC
(23 to 131ºF)
(23 to 131ºF)
–5 to 55ºC
(23 to 131ºF)
(23 to 131ºF)
–5 to 55ºC
(23 to 131ºF)
(23 to 131ºF)
–5 to 55ºC
(23 to 131ºF)
(23 to 131ºF)
Humidity
5 to 95%
noncondensing
noncondensing
5 to 95%
noncondensing
noncondensing
5 to 95%
noncondensing
noncondensing
5 to 95%
noncondensing
noncondensing
5 to 95%
noncondensing
noncondensing
Storage Environment
Temperature
–40 to 185ºF
(–40 to 85ºC)
(–40 to 85ºC)
–40 to 185ºF
(–40 to 85ºC)
(–40 to 85ºC)
–40 to 185ºF
(–40 to 85ºC)
(–40 to 85ºC)
–40 to 185ºF
(–40 to 85ºC)
(–40 to 85ºC)
–40 to 185ºF
(–40 to 85ºC)
(–40 to 85ºC)
Humidity
5 to 95%
noncondensing
noncondensing
5 to 95%
noncondensing
noncondensing
5 to 95%
noncondensing
noncondensing
5 to 95%
noncondensing
noncondensing
5 to 95%
noncondensing
noncondensing
1. Fiber distance of <FD
smf28
>km in SMF28 of equivalent <SR
olb
> dB optical link budget. Assumes D
1550
= 17 ps/nm/km, D
1310
=
3.3 ps/nm/km; fiber+splice+connector loss at 1550 nm = 0.275 dB/km and 1310 nm = 0.55 dB/km; including <P
o
> dB
dispersion penalty at <DL
Rmax
> ps.
2. DFB/DM is typical, but other technologies may be substituted if specifications are met.
3. Minimum and maximum values of the average received power, at the receiver, to achieve 1E-12 BER.
4. Acceptable input wavelength range is 1290 to 1605 nm, but receiver sensitivity is guaranteed only for the indicated range.