MEAN WELL CEN-100-48 Manual Do Utilizador

Página de 3
IP66
110
SELV
SPECIFICATION
MODEL
CEN-100-20
CEN-100-24
CEN-100-30
CEN-100-36
CEN-100-54
CEN-100-48
CEN-100-42
DC VOLTAGE
CURRENT RANGE
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP TIME
VOLTAGE RANGE
Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVER CURRENT
SHORT CIRCUIT
OVER VOLTAGE
OVER TEMPERATURE
20V
24V
30V
36V
54V
48V
42V
0 ~ 4.8A
0 ~ 4A
0 ~ 3.2A
0 ~ 2.65A
0 ~ 1.77A
0 ~ 2A
0 ~ 2.28A
96W
96W
96W
95.4W
95.58W
96W
95.76W
2.0Vp-p
2.7Vp-p
3Vp-p
3.6Vp-p
5Vp-p
4.6Vp-p
4Vp-p
¡Ó10%
¡Ó3.0%
¡Ó5.0%
3000ms / 230VAC 5000ms / 115VAC at full load
90 ~ 295VAC
127 ~ 417VDC
47 ~ 63Hz
PF>0.97/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
88%
89%
90%
90%
91%
91%
90%
22.8 ~ 26V
28 ~ 32V
34 ~ 38V
41 ~ 46V
59 ~ 65V
54 ~ 60V
47 ~ 52V
1.4A/115VAC
0.7A/230VAC
0.5A/277VAC
<0.75mA / 240VAC
95 ~ 110%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed
-30 ~ +70
¢J (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80
, 10 ~ 95% RH
¢J
¡Ó
¢J
¢J
0.03%/
(0 ~ 50
)
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
519.5K hrs min.
MIL-HDBK-217F (25
)
¢J
195*62.5*40.5mm (L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25
of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. Constant current operation region is within 65% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
6. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
7. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
¢J
0.6Kg; 24pcs/15.4Kg/1.11CUFT
Protection type : Shut down o/p voltage, re-power on to recover
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
100
10
(RTH1)
¢J¡Ó ¢J
Protection type : Shut down o/p voltage, re-power on to recover
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC
I/P-FG:2KVAC
O/P-FG:0.5KVAC
UL8750, CSA C22.2 No. 250.0-08(except for 48V, 54V), TUV EN61347-1, EN61347-2-13, IP66, J61347-1, J61347-2-13 approved
I/P-O/P, I/P-FG, O/P-FG: >100M Ohms / 500VDC / 25
/ 70% RH
¢J
SAFETY STANDARDS
Compliance to EN55015, EN61000-3-2 Class C (
65% load) ; EN61000-3-3
¡Ù
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61547, light industry level (surge 4KV), criteria B
13 ~ 20V
15.6 ~ 24V
19.5 ~ 30V
23.4 ~ 36V
35.1 ~ 54V
31.2 ~ 48V
27.3 ~ 42V
RATED CURRENT
4.8A
4A
3.2A
2.65A
1.77A
2A
2.28A
CONSTANT CURRENT OPERATION VOLTAGE
Note.5
17 ~ 22V
22 ~ 27V
27 ~ 33V
33 ~ 40V
49 ~ 58V
43 ~ 53V
37 ~ 46V
VOLTAGE ADJ. RANGE
(SVR1)
CURRENT ADJ. RANGE
(SVR2)
3.12 ~ 4.8A
2.6 ~ 4A
2.08 ~ 3.2A
1.72 ~ 2.65A
1.15 ~ 1.77A
1.3 ~ 2A
1.48 ~ 2.28A
File Name:CEN-100-SPEC 2012-12-26
..
½
Features :
100W Single Output LED Power Supply
C E N - 1 0 0
s e r i e s
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
Universal AC input / Full range (up to 295VAC)
Protections: Short circuit / Over current / Over voltage / Over temperature
Output voltage and constant current level adjustable
Built-in active PFC function
IP66 design for indoor or outdoor installations
Cooling by free air convection
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
3 years warranty
¡E
Class 2 power unit
¡½
Features :
F
EMC IMMUNITY
EMC EMISSION
( except for 48V,54V )
( for 48V,54V only)
COLD START 45A(t
=85 s measured at 50% I
) at 230VAC
width
peak
£g