Tycon Systems TP-SCPOE-1248 Ficha De Dados

Página de 2
 
 
TP-SCPOE Charge Controller Spec Rev 5  13-Apr-12                                                     Specifications Subject to Change Without Notice 
 
 
 
 
POE /Solar Charge Controllers 
Features 
  Dual Input - Charges 12V or 24V Batteries from Solar Panel and / or Passive POE 
  Built in DC to DC converter with various Passive POE output voltages available: 
12V,18V,24V,48V 
  Compact and high temperature operation 
 
Low self consumption < 0.5W
 
Applications 
  Remote Power Systems; Surveillance, Sensors 
 
Wireless Stations ; AP / Client / Repeaters
 
 
UPS Systems ;  Lighting, Fences, Gates
 
Description
 
Tycon Power Systems unique POE/Solar charge controllers have dual inputs to charge batteries from a POE source 
and also a secondary source like solar panels in order to provide redundancy and insure 100% uptime for critical 
applications. The solar panel input takes priority so that when the sun is shining the grid power usage is minimized. 
They have a built in POE inserter with DC to DC converter that delivers 12V, 18V, 24V or 48V at the POE port. They 
have full electronic protections for short circuit, reverse current, overvoltage, overcharge and over discharge.  
They have five LED indicators to give a quick visual status if current is being supplied by a POE source or solar panel, if 
battery is charging, If load output is turned on and a warning if battery is connected with reverse polarity. 
Solar and Battery Connections are via 5 screw terminals for wire size up to 10AWG. POE Input and Output is via 2 
RJ45 shielded connectors. There is a secondary output connector on the back with 5 screw terminals for connecting 
other electronics to the controller using up to 10AWG wire. This secondary output is equal to the battery voltage except 
it also has overvoltage protection. The controllers are externally fused with a standard replaceable fuse.  
DATA SHEET 
TP-SCPOE
 
TP-SCPOE Charge Controller 
There are two separate 12V output 
connections Gnd (or V-) and +12V (or V+): 
Gnd-1 and +12V-1 
Gnd-2 and +12V-2 
 
FG = Frame Ground – Do not connect this to 
the GND 1 or 2 terminals. Frame Ground 
may be left unconnected or connected to 
earth ground.