Alcatel-Lucent OS6850E48 OS6850E48-CH Manual Do Utilizador
Códigos do produto
OS6850E48-CH
3
Alcatel-Lucent OmniSwitch 6850E
AlcAtel-lucent enteRpRiSe
DAtA Sheet
Any power supply can be remotely
connected with a cable that enables
rack mounting with the mounting ears
provided with the unit. This feature allows
for space-sensitive installations requiring
reduced depth, for example, in a wall-
mounted cabinet.
connected with a cable that enables
rack mounting with the mounting ears
provided with the unit. This feature allows
for space-sensitive installations requiring
reduced depth, for example, in a wall-
mounted cabinet.
In addition to the primary and backup
power supplies the OS6850E family
supports the OmniSwitch Backup power
shelf (BPS). With flexible configuration
and advanced management capabilities
the BPS is a powerful and cost effective
way to protect against primary power
supply failure while reducing the closet
space used. The OmniSwitch BPS supplies
redundant power for system power as
well as power over Ethernet (PoE) for
OmniSwitch 6850E devices only. It
can actively backup up to eight devices
attached in either full backup or single
power supply backup mode. **
power supplies the OS6850E family
supports the OmniSwitch Backup power
shelf (BPS). With flexible configuration
and advanced management capabilities
the BPS is a powerful and cost effective
way to protect against primary power
supply failure while reducing the closet
space used. The OmniSwitch BPS supplies
redundant power for system power as
well as power over Ethernet (PoE) for
OmniSwitch 6850E devices only. It
can actively backup up to eight devices
attached in either full backup or single
power supply backup mode. **
** - see OmniSwitch BPS datasheet for additional
information
information
technicAl SpeciFicAtiOnS
physical dimensions
• Chassis size without PS and shelf:
¬ Width: 44.0 cm (17.32 in.)
¬ Depth: 27.0 cm (10.63 in.)
¬ Height: 4.4 cm (1.73 in.)
¬ Depth: 27.0 cm (10.63 in.)
¬ Height: 4.4 cm (1.73 in.)
• Total size including PS and shelf:
¬ Width: 48.2 cm (19.00 in.)
¬ Depth: 44.6 cm (17.56 in.)
¬ Height: 4.4 cm (1.73 in.)
¬ Depth: 44.6 cm (17.56 in.)
¬ Height: 4.4 cm (1.73 in.)
indicators
• Per-port LEDs
¬ RJ-45: PoE, link/activity
¬ SFP: link/activity
¬ SFP+: link/activity
¬ SFP: link/activity
¬ SFP+: link/activity
• System LEDs
¬ Switch ID (indicates the stack ID of the
unit in the stack)
¬ PRI (virtual chassis primary)
¬ System (OK) (chassis HW/SW status)
¬ PWR (primary power supply status)
¬ BPS (backup power status)
¬ PWR (primary power supply status)
¬ BPS (backup power status)
Acoustic levels
Under 48 dB for all models, measured
with a single power supply at room
temperature
temperature
environmental requirements
• Operating temperature: 0°C to +45°C
(+32°F to +113°F)
• Storage temperature: –10°C to +70°C
(+14°F to +158°F)
• Humidity (operating and storage):
5% to 95% non-condensing
Cyclic temperature and humidity tests
of -5°C to +55°C, 5% to 90% Relative
Humidity (RH) for the duration of ~185
hours as per GR-63-CORE
Cyclic temperature and humidity tests
of -5°C to +55°C, 5% to 90% Relative
Humidity (RH) for the duration of ~185
hours as per GR-63-CORE
table 3. OmniSwitch 6850e power consumption, heat dissipation, mtBF and weights
pRODuct
mtBF (hOuRS)
pOweR cOnSumptiOn
(wAttS)*
(wAttS)*
heAt DiSSipAtiOn (Btu/
hOuR)**
hOuR)**
weiGhtS (chASSiS OnlY)
PoE models
OS6850E-P24
186206
84
287
3.88
OS6850E-P24X
178085
94
321
3.91
OS6850E-P48
168662
150
512
4.2
OS6850E-P48X
161769
152
519
4.21
Non-PoE models
OS6850E-24
272970
58
198
3.79
OS6850E-24X
270735
66
225
3.81
OS6850E-48
253153
91
311
3.95
OS6850E-48X
242611
102
348
3.97
OS6850E-U24X
290159
56
191
3.77
* Calculated maximum power consumption. The power consumed by the power device attached to the PoE port is not included.
** Under full traffic load