www.osram.com
Technical operating data
Product
Color
Colortemp.
[K]
Lum. Flux
[lm]
Voltage [V] /
Frequency [Hz]
Input current [A]
Power
[W]
Radiance-
Angle [°]
ST8-HA5-340-865
Cool
Daylight
6500 K
3400
230 V*
200 - 240 V
50 / 60 Hz
0.01 A
28 W
150°
ST8-HA5-340-840
Cool White
4000 K
3400
ST8-HA5-306-830
Warm White
3000 K
3060
LED lamp in T8 shape with G13 socket
Length excl. pins: 1500 mm
Weight: 400g
Length excl. pins: 1500 mm
Weight: 400g
For operation at magnetic ballast
Direct Retrofit for CCG luminaires;
Direct Retrofit for CCG luminaires;
replacement of lamp and included starter
No rewiring necessary at CCG
Extremely robust due to polycarbonate
Extremely robust due to polycarbonate
body
Fully integrated ECG complies to relevant
standards
Powerfactor > 0.9
Up to 50,000 h lifetime
Switching cycles > 200.000
Color Rendering Index (CRI) > 80
Overpower, overheat and short circuit
Up to 50,000 h lifetime
Switching cycles > 200.000
Color Rendering Index (CRI) > 80
Overpower, overheat and short circuit
protected
High color homogeneity
RoHS-conformity, no mercury
Not for operation with ECG, not
RoHS-conformity, no mercury
Not for operation with ECG, not
dimmable
Energy Efficiency Class: A+
Technical Features
All Data are related to the entire lamp. Due to the special conditions of the manufacturing processes of LED the typical data of technical parameters
can only reflect statistical figures and do not necessarily correspond to the actual parameters of each single product which could differ from the typical
data.
* Rated voltage
can only reflect statistical figures and do not necessarily correspond to the actual parameters of each single product which could differ from the typical
data.
* Rated voltage
Innovative LED-lamp, easy and safe to use in CCG
installations as direct retrofit. Energy saving potential of up to
57% by replacing 1.5 m T8 fluorescent tubes.
Instant 100% light without flickering. No mercury.
Applicable in warehouses, cold storage, supply rooms,
corridors, industry, stairways, garages, indirect illumination
etc; for applications with high operating hours.
installations as direct retrofit. Energy saving potential of up to
57% by replacing 1.5 m T8 fluorescent tubes.
Instant 100% light without flickering. No mercury.
Applicable in warehouses, cold storage, supply rooms,
corridors, industry, stairways, garages, indirect illumination
etc; for applications with high operating hours.