Adtran SFP (mini-GBIC) 1490nm TX/1310nm RX, LC 1442120G1 Folheto

Códigos do produto
1442120G1
Página de 2
D
ESCRIPTION
The Small Form-Factor Pluggable (SFP) Gigabit 
Ethernet, Single-Fiber is a bidirectional SFP that 
installs into the Optical Loop Termination (OLT) 
designed to accept SFPs. The SFP provides a single 
optical interface to the GigE physical interface. 
Installed into an appropriate OLT, the SFP provides a 
Gigabit Ethernet interface to the supporting system.
NOTE
To ensure compatibility, refer to the documentation
provided with the OLT.
In a deployment consisting of an OLT with a
1442120G1 SFP installed; the Optical Network Unit
(ONU) should have a complementary 1442120G2 SFP
installed.
The following features are supported on the SFP:
1000Base-LX 1490 nm Transmitter
1000Base-LX 1310 nm Receiver
Optical distance: 20 km maximum
Due to compliance certification requirements, only
SFPs supplied by ADTRAN should be used. ADTRAN
cannot certify system integrity with other SFPs.
OLT
1442120G1
1442120G2
ONU
Rx: 1310 nm
Tx: 1490 nm
Rx: 1490 nm
Tx: 1310 nm
Small Form-Factor Pluggable
1490 nm TX / 1310 nm RX, 20 km
Operational Specifications
Optical Specifications:
Transmit wavelength: 1490 nm
Receive wavelength: 1310 nm
Optical transmit level: –8 dBm to –3 dBm 
Optical receive level: –22 dBm to –3 dBm 
Optical distance: 20 km
Optical connectors: LC
Extended Environmental Support:
Operational temperature range: –40°C to +85°C
Storage temperature range: –40°C to +85°C
Relative humidity to 95%, noncondensing
I
NSTALLATION
Prior to installation, inspect the SFP. If damage has 
occured during shipping, file a claim with the carrier, 
and then contact ADTRAN Customer Support. For 
more information, refer to “Warranty”.
To install the SFP into an appropriate module, 
complete the following steps:
1. Insert the SFP into the SFP cage on the circuit 
board of the host module with the latch handle 
facing outward. Slide the SFP all the way into the 
cage.
NOTE
The latch on the SFP is for removal only. When
removing the SFP, rotate the latch away from the
SFP, the SFP should slide easily out of the cage.
2. Exert adequate pressure to ensure the SFP is 
completely seated in the SFP cage.
3. Do not remove the connector plug until the 
optical fiber connection is made.
It is recommended that the connector plug remain on
whenever the transciever optical fiber connector is
not inserted.
4. Continue the installation and turn-up of the host 
module using the instructions in the Job Aid 
provided with the module, or using the 
Installation and Maintenance Practice (I&M) 
available online at 
www.adtran.com.
CLEI: VAUIAL8P_ _
Product P/N: 1442120G1
Issue Date: 0812
Document P/N: 61442120G1-22B