Intel® Server System SR1640TH TPS 
Environmental and Regulatory Specification 
  
Revision 
1.0 
Intel order number: E94847-001 
84 
8.  Environmental and Regulatory Specifications 
8.1  System Level Environmental Limits 
The following table defines the system level operating and non-operating environmental 
limits.  
Table 78. System Office Environmental Summary 
Parameter 
Limits 
Operating Temperature 
+10
  C to +35  C with the maximum rate of change not to exceed 10  C per 
hour 
Non-Operating 
Temperature 
-40
  C to +70  C  
Non-Operating Humidity 
50%- 90%, non-condensing with a maximum wet bulb of 28
  C 
Acoustic noise  
Sound Pressure: 55 dBA (Rackmount) in an idle state at typical office 
ambient temperature. (23
  C +/- 2  C) Sound Power: 7.0 BA in an idle state at 
typical office ambient temperature. (23 +/- 2 degrees C) 
Shock, operating 
Half sine, 2 g peak, 11 mSec 
Shock, unpackaged 
Trapezoidal, 25 g, velocity change 136 inches/sec ( 40 lbs to > 80 lbs) 
Shock, packaged 
Non-palletized free fall in height 24 inches ( 40 lbs to > 80 lbs) 
Vibration, unpackaged 
5 Hz to 500 Hz, 2.20 g RMS random 
Shock, operating 
Half sine, 2 g peak, 11 mSec 
ESD 
+/-15kV except I/O port +/-8KV per Intel
®
 Environmental test specification 
System Cooling 
Requirement in BTU/Hr 
2050 BTU/hour 
EMI operating 
Required to meet EMI emission requirements, tested as part of system 
 
8.2  Serviceability and Availability 
The system is designed to be serviced by qualified technical personnel only. 
The desired Mean Time To Repair (MTTR) the system is 15 minutes, which includes 
diagnosing the system’s problem. To meet this goal, the system enclosure and hardware 
was designed to minimize the MTTR.  
The following are the maximum times a trained field service technician should take to 
perform the listed system maintenance procedures after diagnosing the system and 
identifying the failed component(s). 
Activity 
Time Estimate 
Plug out the tray 
10 sec 
Remove and replace hard disk drive  
1 min 
Remove and replace power supply module 
30 sec 
Remove and replace system fan(each) 
1 min  
Remove and replace server board(include cable routing) 
10 min 
 
8.3  Replacing the Back up Battery 
The lithium battery on the server board powers the real time clock (RTC) for up to 10 years 
in the absence of power. When the battery starts to weaken, it loses voltage, and the server 
settings stored in CMOS RAM in the RTC (for example, the date and time) may be wrong. 
Contact your customer service representative or dealer for a list of approved devices.