Conrad Energy Rechargeable AAA Battery x4 pc(s) NiMH 1.2V 250900 Ficha De Dados

Códigos do produto
250900
Página de 5
Battery Spec.---PH-AAA900mAh  B/N250900
                                                                     Page  2  of   5
   the following conditions:
              Ambient Temperature: 20±5 .
              Ambient Humidity: 65±20%.
 Test Item
Test    Conditions
Requirements
1. Standard
 Charge
Charge is conducted continuously for 15 hours at the
constant current of 90mA after predischarge at the
constant current of 180mA up to an cut-off voltage of
1.0V.
2.Open-circuit
  Voltage
Voltage between terminals of the charged battery
specified in item(1) is measured after rest for 1 hour.
≥1.25V
3.Capacity
Discharge time of the charged battery specified in
item(1) is measured at 180mA up to an cut-off
voltage of 1.0V after rest for 30 minutes. If the
discharge time doesn't reach the specified value, the
test may be carried out further twice, up to three
times in total.
≥300 minutes
4.Capacity
 (high-rate
   -discharge)
Discharge time of the charged battery specified in
item(1) is measured at 450mA up to an cut-off
voltage of 1.0V after rest for 30 minutes. If the
discharge time doesn't reach the specified value, the
test may be carried out further twice, up to three
times in total.
≥110 minutes
Cycle No.
Charge
Rest
Discharge
1
90mA×16h
none
225mA×140min
2-48
225mA×190min
none
225mA×140min
49
225mA×190min
none
225mA to 1.0V/Batteries
50
90mA×16h
1-4h
225mAto
1.0V/Batteries
5.Cycle Life
Cycles 1 to 50 shall be repeated until the discharge duration on any
50th cycle becomes less than 3h.