When two power shelves are combined, they can produce 7500W -- the remaining 2500W supply 
can be used for N + 1 protection.  
The Cisco Catalyst 4500 E-Series has two DC power options -- one is optimized for data-only 
deployments in service provider central offices (part number PWR-C45-1400DC), and the other is 
used for high-power PoE deployments (PWR-C45-1400DC-P). 
Cisco Catalyst 4500 E-Series External AC Power Shelf and 1400-WDC Power Supply 
with Integrated Power Entry Module 
The Cisco Catalyst 4500 E-Series external AC power shelf must be used in conjunction with the 
1400-WDC-P power supply. In addition to providing power for the chassis, fans, and non-PoE line 
cards, the 1400-WDC power supply contains a power entry module (PEM). The PEM is used to 
pass additional power through to the chassis backplane -- power demanded by the PoE line cards. 
The chassis power trace used for PoE is independent from the one used by the supervisor 
engine(s), fan tray, and backplane components. The 1400-WDC power supply can accept up to 
7500 WDC for data and PoE applications. Up to 1400W can be dedicated for data (supervisor[s], 
fan tray, etc.), while the remaining power is passed through the PEM and is used for PoE. 
When only one external AC power shelf is used (with two 2500-WAC power supplies), it provides 
the 1400-WDC power supply with 5000W of DC power. When two AC power shelves are strapped 
together, the Cisco Catalyst 4500 Series can provide up to 7500W of DC power (3 + 1 redundant). 
Cisco Catalyst 4500 E-Series Service Provider DC Power Supply 
The triple-input 1400-WDC power supply is optimized for service provider central-office 
deployments. By providing multiple inputs, the service provider DC power supply allows central-
office technicians to customize the output power to meet their application needs. Many central-
office deployments require only a fraction of the 1400W available in the service provider power 
supply. With low-current inputs, technicians can connect the supply to smaller fuses and breakers. 
The service provider power supply makes it possible to deploy a Cisco Catalyst 4503 with a single 
15A circuit. Likewise, it is possible to deploy a fully populated Cisco Catalyst 4510R with one 15A 
and two 20A circuits rather than a single 60A connection, which often requires rack rewiring (Table 
3). 
Table 3. 
Triple-Input 1400-WDC Power-Supply Input Modes 
Input Mode 
Input No. 
Input Configuration 
Maximum Total Output Power 
One 12.5A 
412W 
2 or 3 
One 15A 
495W 
1, 2, or 3 
One 12.5A and one 15A 
908W 
2 or 3 
Two 15A 
990W 
1, 2, or 3 
One 12.5A and two 15A 
1400W 
Cisco Catalyst 4500 E-Series Dual Input 4200w Power Supply 
Combined Mode Power Resiliency is an extension of the traditional combined mode power-supply 
behavior; it is applicable only to the 4200W power supply. Each 4200W power supply contains two 
smaller power supplies (called sub-units). In Combined Mode Power Resiliency the system relies 
only on power from three out of four power-supply sub-units. When using 200 VAC, this feature 
helps ensure that 5500W of power are available while the switch is protected against a single input