Lascar Electronics Panel Pilot SGD24-M Ficha De Dados

Códigos do produto
SGD24-M
Página de 5
IN1
4 - 30V
0V
0 - 40V
0 - 40V
IN2
IN1
4 - 30V
0V
0 - 40V
0 - 40V
IN2
ALM1
ALM2
R
R
R = (V
S
 - V
L
)
I
L
V
= Supply voltage
V
= LED Voltage drop
I
= LED current 
4 - 30V
0V
V-
0V
IN1
4 - 20mA
50
200mW
DIGI1
DIGI2
Specifications liable to change without prior warning
Issue 5 04/2011 S.L Applies to SGD 24-M
Page 5 of 5
SGD 24-M
PanelPilot Compatible Smart Graphics Display
Module House
Whiteparish, Salisbury
Wiltshire SP5 2SJ
UK
T +44 (1794) 884567
F +44 (1794) 884616
E sales@lascar.co.uk
4258 West 12th Street
Erie
PA 16505
USA
T +1 (814) 835 0621
F +1 (814) 838 8141
E us-sales@lascarelectronics.com
8th Floor, China Aerospace Centre
143 Hoi Bun Road
Kwun Tong, Kowloon
HONG KONG
T +852 2389 6502
F +852 2389 6535
E saleshk@lascar.com.hk
www.lascarelectronics.com
VARIOUS OPERATING MODES
DIGITAL HOLD
DIGI1 will hold the display for IN1
DIGI2 will hold the display for IN2
ALARM OUTPUTS
Applications that feature an alarm can be connected as above.
ALM1 and ALM2 must not sink more than 10mA maximum.
If supply voltage varies, use an appropriate voltage regulator.
MEASURING 4-20mA
Use a 50 Ω resistor with a 200mW rating.
Setup scaling in software 0V=4.0 and 1V=20.0
Cannot be loop powered. Supply must be isolated for current loop.