VIII 
Pollution Degree 
Degree 2 
 
Pollution Degree Definitions 
Pollution degree 1: No pollution or only dry, non-conductive pollution occurs. The 
pollution has no influence. For example: a clean room or air-conditioned office 
environment. 
Pollution degree 2: Normally only dry, non-conductive pollution occurs. Occasionally 
a temporary conductivity caused by condensation may occur. For example: general 
indoor environment. 
Pollution degree 3: Conductive pollution occurs, or dry, non-conductive pollution 
occurs which becomes conductive due to condensation which is expected. For 
example: Sheltered outdoor environment. 
Pollution degree 4: Pollution that generates persistent conductivity through 
conductive dust, rain, or snow. For example: outdoor locations. 
 
Safety Class 