129 
MIPI
 
D-PHY
 
S
OURCE AND 
C
LOCK 
C
ONTROLS
,
 
B
ASIC
,
 AND 
L
EVELS 
R
IGHT
-H
AND 
D
IALOGS
 
Access the Serial Decode dialog by touching Analysis → Serial Decode on the menu bar. 
Touch the corresponding Setup... button for your decode. The Decode Setup... along with corresponding right-
hand dialogs are shown. 
Decode SetupBasic, and Level dialogs for MIPI D-PHYMIPI CSI-2, and MIPI DSI decoders include the following 
respective controls: 
D-PHY Source and Clock Controls 
Depending on selections made on the DecodeData Probing, and Clock Probing controls located on the Basic 
dialog, corresponding source controls are enabled/disabled for Ddiff (differential clock trace), Dp (Data positive), 
Dn (Data negative), CLKp (Clock Positive), CLKn (Clock Negative). 
 
D-PHY Basic Right-Hand Dialog 
 
 
Decode - Choose from LP & HSHS only, and LP only values. Selections affect remaining fields on the 
dialog as follows: When LP & HS is selected only Clock Probing is available. When HS only is selected both 
Data and Clock Probing
 are available. When LP only is selected, neither Data or Clock Probing are 
available. 
 
Data Probing - This field is only enabled when HS only is selected from the Decode field. When the Data 
Probing field is enabled, choose from Dp & DnDpDn, and Ddiff values. 
 
Clock Probing - This field is enabled when either LP & HS or HS only is selected from the Decode field. 
When the Clock Probing field is enabled, choose from CLKp & CLKnCLKpCLKnCLKdiff, and none (CDR) 
values.