Mask Test Display 
The FlexRay TDP option allows you to verify signal integrity of the communication channel and corresponding 
protocol data simultaneously as follows. Points where the FlexRay signal intersects the mask are indicated with 
red failure marks. 
 
FlexRaybus Measurement Parameter Setup 
 
 
Source - Select the emitting and receiving nodes (Node Module M and N) on the FlexRay channel where 
Propagation Delay, Asymmetric Delay, and Frame TSS Length Change are being measured. 
Note: Jitter is measured on a single channel. 
 
Measurements - Select one of the 4 FlexRaybus Physical Layer Measurement Parameters (on page 86)
Measurement values are shown on the oscilloscope display as boxes are marked. 
 
Probing point - Select the type of line on which you are probing as either BP-BM (diff.) if the signal is a 
differential signal on the communication channel, or RxD-TxD (dig.) if the signal is the two level digital 