Fluke Fluke 4325162 Manual Do Utilizador
Códigos do produto
4325162
1625-2
Users Manual
46
Resistance Measurement (R
~
)
Measuring method:
current and voltage measurement
Measuring voltage:
20 V ac, square pulse
Short circuit current:
>250 mA ac
Measuring frequency:
94, 105, 111, 128 Hz selected manually or automatically (AFC)
Measuring Range
Display Range
Resolution
Accuracy
Operating Error
0.020
Ω…
300 k
Ω
0.001
Ω
…
2.999
Ω
0.001
Ω
3.0
Ω
…
29.99
Ω
0.01
Ω
30
Ω
…
299.9
Ω
0.1
Ω
±(2 % of rdg +2 digit) ±(5% of rdg +5 digit)
300
Ω
…
2999
Ω
1
Ω
3.0 k
Ω
…
29.99 k
Ω
10
Ω
30.0 k
Ω
…
299.9 k
Ω
100
Ω
Measuring time:
typical 6 seconds
Maximum interference
voltage:
voltage:
24 V, with higher voltages measurement will not be started
Maximum overload:
U
rms
maximum = 250 V
Resistance Measurement (R
)
Open circuit voltage:
20 V dc
Short circuit current:
200 mA dc
Formation of measured value:
with 4-pole measurement wires on can be
extended without additional error
extended without additional error
Resistances >1
Ω
in wire can cause additional error of
5 m
Ω
/
Ω
Measuring Range
Display Range
Resolution
Accuracy
Operating Error
0.020
Ω
…3 k
Ω
0.001
Ω
... 2.999
Ω
0.001
Ω
±(2 % of rdg +2 digit)
±(5% of rdg +5 digit)
3.0
Ω
... 29.99
Ω
0.01
Ω
30.0
Ω
... 299.9
Ω
0.1
Ω
300
Ω
…
2999
Ω
1
Ω