Table 5. Pushbuttons (cont.) 
No. Button 
Description 
 
 
  RCD Current multiplier (x1/2, x1, x5, AUTO). 
 Memory STORE. 
  Select Loop impedance test accuracy (, m) – hi 
current trip mode only 
  Continuity test: Rx1/2 (R1+R2), R/2 (R2), x1 (r1), /2 (r2) 
or x5 (rn) in extended documentation mode. 
 
 
 Scroll memory locations. 
  Set memory location codes.  
  Scroll Auto test results. 
  Adjust current for VAR function. 
  Display results if noise is present. 
 
 
  Select RCD: Type AC (sinusoidal), Type AC Selective, 
Type A (half-wave), Type A Selective, Type B (smooth 
DC), or Type B Selective. 
 Memory RECALL. 
 Battery test. 
 Loop RE / IK 
 
 
  RCD test polarity (0, 180 degrees). 
  Insulation test voltage (50, 100, 250, 500, or 1000 V). 
 Memory CLEAR. 
 
 
Turns the tester on and off. The tester will also shut off 
automatically is there is no activity for 10 minutes. 
 
 
Turns the backlight on and off. 
 
 
Starts the selected test. 
The  key is surrounded by a “touch pad”. The touch pad 
measures the potential between the operator and the 
tester’s PE terminal. If you exceed a 100 V threshold, the 
 symbol above the touch pad is illuminated.