Technical Specifications
Summit X350 Series
All Regulatory/Safety Standards 
North American Safety of ITE 
• UL 60950-1 1st Ed., Listed Device (U.S.)
• CSA 22.2#60950-1-03 1st Ed. (Canada)
• Complies with FCC 21CFR 1040.10  
(U.S. Laser Safety)
• CDRH Letter of Approval (U.S. FDA Approval) 
European Safety of ITE
• EN60950-1:2001+A11
• EN 60825-1+A2:2001 (Lasers Safety)
• TUV-R GS Mark by German Notified Body
• 2006/95/EC Low Voltage Directive
International Safety of ITE 
• CB Report & Certificate per IEC 60950-1:2001 
+ National Differences
• AS/NZS 60950-1 (Australia/New Zealand)   
EMI/EMC Standards 
North America EMC for ITE 
• FCC CFR 47 part 15 Class A (U.S.A.)
• ICES-003 Class A (Canada)
European EMC Standards
 
• EN 55022:2003 Class A
• EN 55024:A2-2003 Class A includes  
IEC 61000-4-2, 3, 4, 5, 6, 11
• EN 61000-3-2,8-2000(Harmonics)
• EN 61000-3-3 1995+A1:2001(Flicker)
• ETSI EN 300 386 v1.3.3, 2005-04  
(EMC Telecom munications)
• 2004/108/EC EMC Directive
International EMC Certifications
• CISPR 22: 2005, Class A  
(International Emissions)
• CISPR 24:A2:2003 Class A  
(International Immunity)
• IEC/EN 61000-4-2:2001 Electrostatic 
Discharge, 8kV Contact, 15 kV Air, Criteria A
• EC/EN 61000-4-3:2002 Radiated Immunity 
10V/m, Criteria A
• EC/EN 61000-4-4:2004 Transient Burst,  
1 kV, Criteria A
• IEC/EN 61000-4-5:2001 Surge, 2 kV L-L,  
2 kV L-G, Level 3, Criteria A
• IEC/EN 61000-4-6:2004 Conducted Immunity, 
0.15-80 MHz, 10V/m unmod. RMS, Criteria A
• EC/EN 61000-4-11:2004 Power Dips & 
Interruptions, >30%, 25 periods, Criteria C
Country Specific
• VCCI Class A (Japan Emissions)
• ACMA (C-Tick) (Australia Emissions)
• KCC Mark EMC Approval (Korea)     
Telecom Standards 
• EN/ETSI 300 386:2001  
(EMC Telecommunica tions)
• EN/ETSI 300 019 (Environmental  
for Telecommunications)
IEEE 802.3 Media Access Standards 
• IEEE 802.3ab 1000BASE-T
• IEEE 802.3z 1000BASE-X
• IEEE 802.3ae 10GBASE-X
• IEEE 802.3an 10GBASE-T
Environmental Standards
 
• EN/ETSI 300 019-2-1 v2.1.2 (2000-09) -  
Class 1.2 Storage
• EN/ETSI 300 019-2-2 v2.1.2 (1999-09) -  
Class 2.3 Transportation
• EN/ETSI 300 019-2-3 v2.1.2 (2003-04) -  
Class 3.1e Operational
• EN/ETSI 300 753 (1997-10) – Acoustic Noise
•  ASTM D3580 Random Vibration Unpackaged 1.5G  
Warranty 
• Ltd. Lifetime with express Advanced Hardware 
Replacement (for products shipped from 
Extreme Networks on or after June 29, 2009)
• For warranty details,  
visit www.extremenetworks.com/go/warranty
Summit X350-48t
General Specifications 
Performance
 
• 176 Gbps switch fabric bandwidth
• 101.2 Mpps frame forwarding rate
•  9,216 Byte maximum packet size (Jumbo Frame)
• 25 load sharing trunks, up to 8 members  
per trunk
• 8 QoS queues/port
• 4,094 VLANs (Port, Protocol, IEEE 802.1Q)
• 1,024 centralized ACL rules per 24-ports  
Forwarding Tables
 
• Layer 2/MAC Addresses: 8K  
Rate Limiting 
• Ingress bandwidth policing/rate limiting  
per flow
•  Egress bandwidth rate shaping per egress queue 
and per port
• Rate Limiting Granularity: 64Kbps
• Available Rate Limiters: 1,024 per 24-port
Indicators
 
• Per port status LED including power status 
• System Status LEDs: management, fan  
and power 
Ports
 
• 48 ports 10/100/1000BASE-T with  
auto-speed and auto-polarity
• 4 ports 1000BASE-X SFP (shared PHY with 4 
10/100/1000BASE-T ports)
• 1 port Serial (control port)
• 1 10/100BASE-T out-of-band management port
• Per port status LED including power status
• Slot for XGM2 10 Gigabit Option Module 
External Power Supply Support
• EPS-500
Physical Specifications 
Dimensions
 
• Height: 1.73 Inches/4.4 Cm
• Width: 17.35 Inches/44.1 Cm
• Depth: 17.0 Inches/43.2 Cm
• Weight: 15.75 Lbs / 7.14 Kg
Operating Specifications 
Temperature 
• Operating Temperature Range:  
0° C to 40° C  (32° F to 104° F)
• Operating Humidity: 10% to 93% relative 
humidity, non-condensing
• Operational Shock (Half Sine):  
30 m/s2 (3g), 11ms, 60 Shocks
• Operational Random Vibration:  
3 – 500 MHz @ 1.5g rms 
Storage & Transportation Conditions (Packaged)
 
• Transportation Temperature:  
-40° C to 70° C (- 40° F to 158° F)
• Storage and Transportation Humidity:  
10% to 95% RH, non-condensing
• Packaged Shock (Half Sine):  
180 m/s2 (18g), 6ms, 600 shocks
• Packaged Sine Vibration: 5 – 62 Hz @ Velocity 
5mm/s, 62 – 500 Hz @ 0.2 G
• Packaged Random Vibration: 5 – 20 Hz @ 1.0 
ASD w/-3dB/oct. from 20 – 200 Hz
• 14 drops min on sides & corners @ 42”    
(<15kg box) 
Power & Accoustic Sound 
• Voltage Input Range: 90 – 264V
• Nominal Input Ratings: 100~240V,  
50/60 Hz, 1.5A
• Nominal Input Current: 1.45A @ 100V~ (lowline) 
0.65A @ 230V~ (highline)
• Maximum In-Rush Current: 30A @ 115V;  
60A @ 230V/6.0 Hz, Max Load
• Efficiency: 80% with 60% – 100% load
• Line Frequency Range: 47 – 63 Hz
• Nominal Frequency Range: 50 – 60 Hz
• Power Supply Input Socket: IEC 320 C14
• Power Cord Input Plug: IEC 320 C13
• Heat Dissipation: 115W (393 BTU/hr)
• Nominal Maximum Power Consumption:  
115W (393 BTU/hr)
• Sound Power in accordance with  
EN 300 753 (10-1997)
• Sound Power: 49.9 dBA
• Declared Sound Power: 6.4 belsA per  
ISO 7779 & ISO 9296
• Bystander Sound Pressure in accordance with 
NEBS GR-63 Issue 2
• Bystander Sound Pressure: 39.7 dBA