Finder 49.61.8.012.0060 Relay Interface Module 1 changeover 12 Vac 49.61.8.012.0060 Ficha De Dados

Códigos do produto
49.61.8.012.0060
Página de 8
6
Contact specification
F 49 - Electrical life (AC) v contact current
Types 49.31/61/81
• When switching a resistive load (DC1) having voltage and current   
values under the curve, an electrical life of ≥ 100·10
3
can be expected.
• In the case of DC13 loads, the connection of a diode in parallel with
the load will permit a similar electrical life as for a DC1 load.
Note: the release time for the load will be increased.
H 49 - Maximum DC1 breaking capacity
Types 49.31/52/61/72/81
Cycles
F 49 - Electrical life (AC) v contact current
Types 49.52/72
Resistive load - cos
ϕ = 1
Inductive load - cos
ϕ = 0.4
49 Series - Relay interface modules 8 - 10 - 16 A
Cycles
Resistive load - cos
ϕ = 1
Inductive load - cos
ϕ = 0.4
limit for
49.31
DC breaking current (A)
DC voltage (V)
49.52/72 -  2 contacts in series
single contact
49.61/81 current limit
49.31 current limit
49.52/72 current limit