Finder 13.91.8.230.0000 Ficha De Dados

Página de 8
Call relay with reset 
command
1 CO (SPDT) + 1 NO (SPST-NO)
35 mm rail (EN 60715) 
mount
17.5 mm wide
Features
13.01 - Quiet operating electronic step/
monostable relay
1 Pole output contact
13.11 - Call & Reset Relay 1 Pole output contact
13.12 - Call & Reset Relay 2 Pole output contact
Selectable Step or Monostable operation
(type13.01)
Call relay with reset command suitable for 
residential and commercial applications: 
public bathroom, hospital, hotel 
(type 13.11/13.12)
Control input can be continuously applied
Longer mechanical and electrical life, and 
much quieter than electromechanical step 
relays
Suitable for SELV applications 
according to IEC 364, (type 13.01)
Type 13.01 available also for supply 
12 and 24 V AC/DC
Type 13.12 available at 12 V AC/DC and
24 V AC/DC only
35 mm rail (EN 60715) mount
Cadmium free contact material (type 13.01)
1 CO (SPDT)
1 CO (SPDT)
1 CO (SPDT) + 1 NO (SPST-NO)
16/30 (120 A - 5 ms)
12/30
8/15
250/400
250/400
250/400
4,000
3,000
2,000
750
750
400
2,000
1,200
800
750
400
250
1,000
600
400
2,000
1,200
800
1,000 (10/10)
500 (5/5)
300 (5/5)
AgSnO
2
AgCdO
AgCdO
12 - 24 * - 110…125 - 230…240    
230...240
12 - 24
12 - 24 *
12 - 24
2.5/2.5
1.7/0.7 **
3/2.5 **
(0.8…1.1)U
N
(0.8…1.1)U
N
(0.8…1.1)U
N
(0.9…1.1)U
N
(0.8…1.1)U
N
100 · 10
3
100 · 10
3
100 · 10
3
continuous
continuous (100 ms minimum)
continuous (100 ms minimum)
1,000
1,000
1,000
4,000
2,000
2,000
–10…+60
–10…+60
–10…+60
IP 20
IP 20
IP 20
Contact specification
Contact configuration
Rated current/Maximum peak current
A
Rated voltage/Maximum switching voltage V AC
Rated load AC1 
VA
Rated load AC15 (230 V AC)
VA
Nominal lamp rating: incandescent (230 V) W
compensated fluorescent (230 V) W
uncompensated fluorescent (230 V) W
halogen (230 V) W
Minimum switching load
mW (V/mA)
Standard contact material
Supply specification
Nominal voltage (U
N
)
V AC (50/60 Hz)
V DC
Rated power AC/DC
V A (50 Hz)/W
Operating range
AC (50 Hz)
DC
Technical data
Electrical life at rated load in AC1
cycles
Maximum impulse duration
Dielectric strength between: open contacts V AC
supply - contacts V AC
Ambient temperature range
°C
Protection category 
Approvals (according to type)
Call relay with reset 
command
1 CO (SPDT)
35 mm rail (EN 60715) 
mount
17.5 mm wide
Step or monostable relay
35 mm rail (EN 60715) 
mount
1
13 Series - Electronic step/monostable & call/reset relays 8 - 12 - 16 A
13.01
13.11
13.12
* For version 24 V U
max
= 33.6 V
** During impulse only.
For outline drawing see page 7
I-2013, www
.finder
net.com