Technical data
Conductor data
Structure of individual litz in acc. with VDE 0295 / smallest
wire diameter
Class 2-6 // 0.34 mm²: 0.1 mm; 0.5 - 0.75 mm²: 0.15 mm
Wire insulation material
PVC/PE
Wire diameter including insulation
≤ 2.5 mm
Minimum external conductor diameter
4 mm
Maximum external conductor diameter
7.5 mm
Tightening torque, union nut
2.5 Nm
Wrench size, union nut
22 mm
Note on the frequency of connections
if the conductor is connected more than once, seal and cap may
need to be replaced.
Conductor cross section stranded min.
0.34 mm²
Conductor cross section stranded max.
0.75 mm²
Conductor cross section AWG/kcmil min.
22
Conductor cross section AWG/kcmil max
18
Insulation material
Housing material
PA
Material of the moulding mass
PUR
Contact material
Steel/copper
Contact surface material
Sn
Pin assignment
Slot/position = Wire color or connection
1 / 4 (A) = WH
Slot/position = Wire color or connection
2 / 4 (A) = GN
Slot/position = Wire color or connection
3 / 4 (A) = YE
Slot/position = Wire color or connection
4 / 4 (A) = GY
Slot/position = Wire color or connection
5 / 4 (A) = PK
Slot/position = Wire color or connection
6 / 4 (A) = RD
Slot/position = Wire color or connection
1-6 / 1 (+ 120 V) = BN
Slot/position = Wire color or connection
1-6 / 3 (0 V) = BU
Slot/position = Wire color or connection
1-6 / 5 (PE) = GN/YE
Cable
Cable type
PUR/PVC black
Cable type (abbreviation)
PUR
Cable abbreviation
LiYY11Y-HF
UL AWM style
20549
Conductor cross section
6x 0.34 mm² (signal line)
Conductor cross section
3x 0.75 mm² (power line)
AWG signal line
22
AWG power supply
18
Conductor structure signal line
19x 0.15 mm
Conductor structure, voltage supply
42x 0.15 mm
Core diameter including insulation
1.3 mm ±0.1 mm (signal line)