1-1 Precautions in Using Aluminum Electrolytic Capacitors
Please note the following recommendations when use capacitors:
10. Keep the following clearance between the vent of the capacitor
and the case of the appliance . Do not
block the operation of the
vent , unless otherwise described on the
catalogues or product
specifications . The narrower clearance may adversely
affect the
vent operation and result in an explosion of the capacitor .
Case diameter
Clearance
6.3 to 16 mm
2 mm minimum
18 to 35 mm
3 mm minimum
40 mm & up
5 mm minimum
Fig.1-1
-size electrolytic capacitors , nothing abnormal will be occurred if
and insulation sleeve of electrolytic capacitors . In the case of small
dipping is performed at less than 260ºC for less than 10 seconds .
merely standard values .
Before using the products , please read the notes in this catalogue
carefully for proper use .
notice for product improvement . Therefore , please confirm the
specification before ordering products .
The general characteristics , reliability data , etc ., described in this
catalogue should not be construed as guaranteed values , they are
9. Do not apply excessive force to the lead wires or terminals .
If excessive force is applied to the lead wires and terminals , they
Attention
may be broken or their connections on the internal elements may
be affected . (For strength of terminals , please refer to JIS C5102
and C5141 . )
The description in this catalogue is subject to change without prior
7. Be careful of temperature and time when soldering .
care must be taken that the soldering temperature is not too high
and that the dipping time is not too long .
Otherwise , there will be adverse effect on the electrical characteristics
When soldering a printed circuit board with various components ,
8. Cleaning circuit boards after soldering .
Halogenated hydrocarbon cleaning solvents are not recommended
for use in cleaning capacitors supplied with exposed end seals .
Where cleaning with a halogenated solvent is desired , capacitors
should be ordered with an Epoxy-coated end seal .
6. When capacitors have been left unused for long time , use them only
after due voltage treatments . Long storage of capacitors tends to
rise their leakage current levels . In such cases , be sure to provide
temperature range . Use at room temperature will ensure a longer
life .
5. The electrolytic capacitor is not suitable for circuits which are
charged and discharged repeatedly .
Use the electrolytic capacitor at current value within the permissible
ripple range . If the ripple exceeds the specified value , request
the necessary voltage treatment before use .
If used in circuits which are charged and discharged repeatedly , the
capacitance value may drop or the capacitor may be damaged .
Please consult our engineering department for assistance in these
applications .
capacitors for high ripple current applications .
Use the electrolytic capacitors according to the specified operation
4. Ascertain the operation temperature range .
1. Electrolytic capacitors for DC applications require polarization .
Confirm the polarity before use . The circuit life may be shortened
or the capacitor may be damaged if insert in reversed polarity . For
use on circuits whose polarity is occasionally reversed , or whose
polarity is unknown , use non-polar capacitors . Also note that the
electrolytic capacitors cannot be used for AC applications .
3. Do not allow excessive ripple current passing.
2. Do not apply a voltage exceeding the capacitor's voltage rating.
If a voltage exceeding the capacitor's voltage rating is applied , the
capacitor may be damaged by increased leakage current . When
using the capacitor with AC voltage do not exceed the rated voltage .
ø
ø
ø
ø
ø
•
•
•