Panasonic S1DXMM2C10HAC240V-S Time Delay Relay, Timer, 2 changeover contacts Switch on delay, Pulse (On-Start), Pulse (O S1DXMM2C10HAC240V-S Ficha De Dados

Códigos do produto
S1DXMM2C10HAC240V-S
Página de 7
S1DXM-A/M
4
SPECIFICATIONS
Notes: *1. Unspecified measuring conditions are rated operating voltage (in case of DC type, ripple rate of 5% or less), ambient temp. 20°C 
68°F
, and power off time 1 second.
*2. When using with a transmission wave rectification, vibration resistance and shock resistance properties worsen compared to when using a stabilized power supply.
*3. Power one-shot 1 s range: +2% and 10 ms
Item
Specifications
Rating
Rated operating voltage
24VAC
100 to 120VAC
200 to 220VAC
220 to 240VAC
12VDC
24VDC
Rated frequency
50/60Hz common
Rated power 
consumption
Max. 3 VA 
(at 24 VAC)
Max. 3 VA 
(at 100 VAC)
Max. 3 VA 
(at 200 VAC)
Max. 3 VA 
(at 220 VAC)
Max. 2 W 
(at 12 VDC)
Max. 2 W 
(at 24 VDC)
During time delay
Approx. 3mA
Approx. 3mA
Approx. 3mA
Approx. 3mA
Approx. 5mA
Approx. 3mA
After time delay
Approx. 80mA
Approx. 20mA
Approx. 13mA
Approx. 13mA
Approx. 70mA
Approx. 40mA
Rated control capacity
Timed -out 2 Form C: 7A 250V AC (resistive load)
Timed -out 4 Form C: 5A 250V AC (resistive load)
Operation mode
S1DXM-A
Power on delay operation fixed
(Power display: ON/green; Operation display (when output is on): UP/orange)
S1DXM-M
4 switchable operations: Power ON-delay/Power Flicker OFF start/Power Flicker ON start/Power One-shot
(Power display: ON/green; Operation display (when output is on): UP/orange)
Time accuracy*
1
Operating time fluctuation & 
Power off time change error
Max. ±1 %, (power off time change at the range of 0.1 s to 1 h), 1 s range: Max. ±1 % and 10 ms*
3
Voltage error
Max. ±1 % (at the operating voltage changes between –20 to +10%), 1 s range: Max. ±1 % and 10 ms*
3
Temperature error
Max. ±5% (at 20°C ambient temp. at the range of –10 to +50°C 
+14 to +122°F
)
Setting error
Max. ±10%, 1 s range: Max. ±10% and 20 ms
Contact
Contact arrangement
Timed-out 2 Form C, Timed-out 4 Form C
Contact resistance (Initial value)
Max. 100m
Ω (at 1A, 6V DC)
Contact material
Timed-out 2 Form C type: Silver alloy, Au plating
Timed-out 4 Form C type: Silver alloy, Au plating
Life
Mechanical (constant)
Min. 10
7
Electrical (constant)
2
×10
5
 (at rated control capacity)
Mechanical
Vibration 
resistance
Functional
10 to 55Hz: 1 cycle/min double amplitude of 0.25mm (10min on 3 axes)
Destructive
10 to 55Hz: 1 cycle/min double amplitude of 0.375mm (1h on 3 axes)
Shock 
resistance
Functional
Min. 98m/s
2
 (4 times on 3 axes)
Destructive
Min. 980m/s
2
 (5 times on 3 axes)
Electrical
Allowable operating voltage range
80 to 110% of rated operating voltage
Reset time
Max. 0.1s
Insulation resistance (Initial value)
Between live and dead metal parts, between input and output, between contact sets, between contacts
Min. 100 M
Ω (at 500 V DC megger)
Breakdown voltage (Initial value)
Between live and dead metal parts: 1,500 Vrms for 1 min
Between input and output: 1,500 Vrms for 1 min
Between contact sets: 1,500 Vrms for 1 min
Between contacts: 1,000 Vrms for 1 min
Max. temperature rise
70°C 
158°F
Operating 
conditions
Ambient temperature
–10 to 50°C 
+14 to 122°F
Ambient humidity
35 to 85% RH (non-condensing)
Air pressure
860 to 1060 hPa
Ripple rate
DC type only, transmission wave rectification (ripple rate: approx. 48%)*
2
Mass (Weight)
Approx. 45 g
Protective construction
IEC standard: IP40 (IP50 when using ADX18008 protective cover)
06/2006