Finder 48.31.7.012.0050 Relay 48.31.7.012.0050 Ficha De Dados
Códigos do produto
48.31.7.012.0050
48.62/82
48.61/81
2 CO (DPDT)
10/20
250/400
2,500
500
0.37
10/0.3/0.12
300 (5/5)
AgNi
—
12 - 24 - 125
—/0.5
—
(0.8…1.5)U
N
—/0.4 U
N
—/0.1 U
N
20 · 10
6
100 · 10
3
12/12 (DC)
6 (8 mm)
1,000
–40…+70
IP 20
•
2 pole, 10 A
•
Screw terminal and screwless terminal
•
35 mm rail (EN 60715) mounting
1 & 2 Pole relay interface modules,
15.8 mm wide
Ideal interface for PLC and electronic systems
15.8 mm wide
Ideal interface for PLC and electronic systems
48.61 - 1 Pole 16 A (screw terminal)
48.81 - 1 Pole 16 A (screwless terminal)
48.62 - 2 Pole 10 A (screw terminal)
48.82 - 2 Pole 10 A (screwless terminal)
48.81 - 1 Pole 16 A (screwless terminal)
48.62 - 2 Pole 10 A (screw terminal)
48.82 - 2 Pole 10 A (screwless terminal)
•
AC coils or DC sensitive coils
•
Instant ejection of relay using plastic
retaining clip
retaining clip
•
Supply status indication and EMC coil
suppression module as standard
suppression module as standard
•
Identification label
•
UL Listing (certain relay/socket combinations)
•
35 mm rail (EN 60715) mounting
1 CO (SPDT)
16*/30
250/400
4,000
750
0.55
16/0.3/0.12
500 (10/5)
AgCdO
12 - 24 - 110 - 120 - 230
12 - 24 - 125
1.2/0.5
(0.8…1.1)U
N
(0.8…1.5)U
N
0.8 U
N
/0.4 U
N
0.2 U
N
/0.1 U
N
10 · 10
6
100 · 10
3
7/4 (AC) - 12/12 (DC)
6 (8 mm)
1,000
–40…+70
IP 20
•
1 pole, 16 A
•
Screw terminal and screwless terminal
•
35 mm rail (EN 60715) mounting
Contact specification
Contact configuration
Rated current/Maximum peak current
A
Rated voltage/Maximum switching voltage V AC
Rated load AC1
VA
Rated load AC15 (230 V AC)
VA
Single phase motor rating (230 V AC)
kW
Breaking capacity DC1: 30/110/220V
A
Minimum switching load
mW (V/mA)
Standard contact material
Coil specification
Nominal voltage (U
N
)
V AC (50/60 Hz)
V DC
Rated power AC/sens. DC
VA (50 Hz)/W
Operating range
AC
sens. DC
Holding voltage
AC/DC
Must drop-out voltage
AC/DC
Technical data
Mechanical life
cycles
Electrical life at rated load AC1
cycles
Operate/release time
ms
Insulation between coil and contacts (1.2/50 µs) kV
Dielectric strength between open contacts
V AC
Ambient temperature range
°C
Protection category
Approvals relay (according to type)
* For currents >10 A, contact terminals
must be connected in parallel
(21 with 11, 24 with 14, 22 with 12).
(21 with 11, 24 with 14, 22 with 12).
48.61 / 48.62
Screw terminal
Screw terminal
48.81 / 48.82
Screwless terminal
Screwless terminal
For outline drawing see page 7
Features
3
II-2014, www
.finder
net.com
B
48 Series - Relay interface modules 8 - 10 - 16 A
48
SERIES