Finder 88.12.0.230.0002 Time Delay Relay, Timer, DPDT-CO 24 - 230 V DC/AC IP40 88.12.0.230.0002 Ficha De Dados

Códigos do produto
88.12.0.230.0002
Página de 6
88.02
88.12
Features
Multi-voltage and multi-function timer range
Front panel or socket mount   
8 - 11 pin plug-in version available
Time scales from 0.05s to 100h
“1 delayed contact +1 instantaneous
contact” version available (type 88.12)
Front panel mounting fixing included
90 series sockets
Multi-function
11 pin
Plug-in for use with 90 series sockets
AI: On-delay
DI: Interval
GI: Pulse delayed
SW: Symmetrical flasher (starting pulse on)
Al a: On-delay (2 timed contacts)
Al b: On-delay (1 timed + 1 instantaneous contact)
Dl a: Interval (2 timed contacts)
Dl b: Interval (1 timed + 1 instantaneous contact)
GI: Pulse delayed
SW: Symmetrical flasher (starting pulse on)
2 CO (DPDT)
2 CO (DPDT)
8/15
5/10
250/250
250/400
2,000
1,250
400
250
0.3
0.125
8/0.3/0.12
5/0.3/0.12
300 (5/5)
500 (5/5) 
AgNi
AgCdO
24…230
24…230
24...230
24...230
2.5 (230 V)/1 (24 V)
2.5 (230 V)/1.5 (24 V)
20.4…264.5
20.4…264.5
20.4…264.5
20.4…264.5
(0.05 s…5 h) - (0.05 s…10 h) - (0.05 s…50 h) - (0.05 s…100 h)
± 1
± 1 
300
200
50
± 3
± 3
100·10
3
100·10
3
–10…+55
–10…+55
IP 40
IP 40
Multi-function
8 pin, 2 timed contacts or 
1 timed + 1 instantaneous contact
Plug-in for use with 90 series sockets
BE: Off-delay with control signal
CE: On- and off-delay with control signal
DE: Interval with control signal on
without control signal
with control signal
without control signal
Contact specification
Contact configuration
Rated current/Maximum peak current
A
Rated voltage/Maximum switching voltage V AC
Rated load AC1  
VA
Rated load AC15 (230 V AC)
VA
Single phase motor rating (230 V AC) 
kW
Breaking capacity DC1: 30/110/220 V
A
Minimum switching load
mW (V/mA)
Standard contact material
Supply specification
Nominal voltage (U
N
)
V AC (50/60 Hz)
V DC
Rated power AC/DC
VA (50 Hz)/W
Operating range
V AC
V DC
Technical data
Specified time range
Repeatability
%
Recovery time
ms
Minimum control impulse
ms
Setting accuracy-full range
%
Electrical life at rated load AC1
cycles
Ambient temperature range
°C
Protection category
Approvals (according to type)
1