Weidmueller Weidmüller MOS 12-28VDC / 5VTTL 89379300 8937930000 Ficha De Dados

Códigos do produto
8937930000
Página de 7
Data sheet...
 
MICROOPTO
MOS 12-28VDC/5VTTL
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
D-32758 Detmold
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-292083
www.weidmueller.com
Technical data
 
 
Creation date November 19, 2012 2:18:04 PM CET
 
Catalogue status 06.11.2012 / We reserve the right to make technical changes.
2
Dimensions and weights
 
Width
6.1 mm
  Height
88 mm
Depth
98 mm
  Net weight
34 g
 
Temperatures
 
Operating temperature
-25 °C...+60 °C
  Storage temperature
-40 °C...+60 °C
 
Probability of failure
 
MTTF
2,047 Years
   
 
Connection data
 
Clamping range, rated connection
2.5 mm²
  Clamping range, rated connection, min. 0.5 mm²
Clamping range, rated connection, max. 4 mm²
   
 
Control side
 
Rated control voltage
12 V DC...28 V DC
  Power rating
150 mW
Input frequency
100 kHz
  Cut-in (switch-on) voltage
> 10.7 V
Dropout voltage
< 10.6 V
  Protective circuit, control side
Varistor, rev. polarity
protection
Status display on control side
Green status LED
  Rated auxiliary voltage
5 V DC ±5 %
 
Load side
 
Rated switching voltage
5 V TTL
  Continuous current
max. 50 mA
Rated switching current
50 mA
  Switch-on delay
typical. < 1 µs
Switch-off delay
typical. < 4 µs
  Load category
LC A
Leakage current
< 1 µA
  Protective circuit, load side
Varistor
Voltage drop at max. load
90 mV
  Short-circuit-proof
No
Rated auxiliary voltage
5 V DC ±5 %
   
 
General data
 
Solid-state type
TTL
  No. of poles
1
Conductor connection system
Screw connection
  Humidity
40 °C / 93 % rel. humidity,
no condensation
UL 94 flammability rating
V-0
  Standards
DIN EN 50178, GL 2003-
Vl-Abs. 9, IEC 62314,
UL508
 
Insulation coordination
 
Rated voltage
300 V
  Clearance and creepage distances for
control side - load side
> 3 mm
Dielectric strength for control side - load
side
1.2 kV
eff
 / 1 min.
  Dielectric strength to mounting rail
1.2 kV
eff
 / 1 min.
Impulse withstand voltage
4 kV (1.2/50 µs)
  Pollution severity
2
Surge voltage category
III
   
 
Further details of approvals
 
Standards
DIN EN 50178, GL 2003-
Vl-Abs. 9, IEC 62314,
UL508