Technical data
Contact side
Limiting continuous current
8 A
Interrupting rating (ohmic load) max.
190 W (at 24 V DC)
Interrupting rating (ohmic load) max.
85 W (at 48 V DC)
Interrupting rating (ohmic load) max.
60 W (at 60 V DC)
Interrupting rating (ohmic load) max.
44 W (at 110 V DC)
Interrupting rating (ohmic load) max.
60 W (at 220 V DC)
Interrupting rating (ohmic load) max.
2000 VA (for 250 V AC)
Switching capacity in acc. with DIN VDE 0660/IEC 60947
2 A (at 24 V, DC13)
Switching capacity in acc. with DIN VDE 0660/IEC 60947
0.2 A (at 250 V, DC13)
Switching capacity in acc. with DIN VDE 0660/IEC 60947
3 A (at 24 V, AC15)
Switching capacity in acc. with DIN VDE 0660/IEC 60947
3 A (at 120 V, AC15)
Switching capacity in acc. with DIN VDE 0660/IEC 60947
3 A (at 250 V, AC15)
General
Test voltage relay winding/relay contact
5 kV AC (50 Hz, 1 min.)
Test voltage relay contact/relay contact
2.5 kV AC (50 Hz, 1 min.)
Operating mode
100% operating factor
Mechanical service life
3 x 10
7
cycles
Standards/regulations
IEC 60664
Standards/regulations
EN 50178
Standards/regulations
IEC 62103
Rated surge voltage / insulation
Basic insulation
Pollution degree
3
Surge voltage category
III
Mounting position
Any
Assembly instructions
Can be aligned without spacing (> 70 °C ≥ 2.5 mm)
classifications
eCl@ss
eCl@ss 4.0
27371104
eCl@ss 4.1
27371104
eCl@ss 5.0
27371001
eCl@ss 5.1
27371001
eCl@ss 6.0
27371001
eCl@ss 7.0
27371001
eCl@ss 8.0
27371001
ETIM
ETIM 2.0
EC000196
ETIM 3.0
EC000196
ETIM 4.0
EC000196