ABUS SE1010 Manual Do Utilizador

Página de 4
Changing switch mode (impulse/permanent contact) 
 
1.  The factory setting of the key switch is 
permanent contact. To change the switch 
mode: 
2.  Remove the upper part of the clamp and 
swing it to the side.  
3.  The key switch is now set to impulse mode. 
 
Installation 
1. 
Using the key supplied, unscrew the cover screws and remove the cover 
plate. 
2. 
Remove the two PCB screws on the left and right of the cylinder. 
3. 
Pull the cylinder and PCB carefully upwards and out. 
4. 
Use the back of the key-switch case as a template for marking the drill 
holes (2). Drill the holes for the fixing screws.  
5. 
Pull the connector cable through the opening provided. 
6. 
Fix the casing to or in the wall. 
7. 
Connect the cables to the terminal block (8) as described. 
8. 
Replace the PCB in the casing, replace the cover (1) and tighten the cover 
screws. Make sure that the sealing ring sits firmly in the housing groove. 
 
 
Technical data 
 
Voltage supply LED

10–15 V DC

Max. power consumption per LED

2mA

Maximum contact capacity

30V DC / 0.5A

Dimensions (surface fitting)

85 x 114 x 42mm (WxHxD)

Dimensions (flush fitting)

106 x 134 x 42mm (WxHxD)

Protection type

IP55

Number of contacts

3 (switchable)

Weight

450g

 
The manufacturer reserves the right to make technical modifications without 
prior notice.  
Permanent 
Impulse