Installation Instructions 
 
 
 
 
 
The surface-heating elements have been tested to
 
VDE Standards in 
accordance with DIN EN60335-1, DIN EN60335-2-96 and DIN EN50366. 
 
These instructions must be read carefully before commencing the installation procedure.  Whenever work is 
being  undertaken  on  this  heating  equipment  the  relevant  VDE-Regulations  must  be  readily  available  and 
handed  directly  to  the  installer.  These  instructions  relate  to  the  Surface-heating  Elements    0,75  square 
metre  to  10  square  meters.  The  manufacturer  guarantees  the  product  for  a  period  of  10  years.  This 
guarantee does not include any preparatory work or replacement of surface covering material.  Installation 
must be carried out by a qualified person and be made strictly in accordance with the appropriate Standards 
and Regulations, such as, for example, VDE 0700 - Part 753 and VDE 0100 - Part 701. Please pay careful 
attention to the information given on the Guarantee Card. The specified entries (measured values made on 
the  completed  installation)  must  be  recorded  on  that  Guarantee  Card.  The  manufacturer  will  not  accept 
responsibility for any faults which can be attributed to measurements which either have not been made and 
recorded at all or which have been made incorrectly.      
 
Warning notice 
Warning  notice  according to  A2  EN 60335-1:2006: This  surface-heating element  is  not  intended for  being 
used  by  persons  (including  children)  with  limited,  physical,  sensory  or  mental  abilities  or  in  absence  of 
experience and/or in absence of knowledge, unless they are supervised by a person which is responsible 
for  their  security  or  received  instructions  from  this  person  mentioned  above,  how  this  surface-heating 
element is to be used. 
Children should be supervised, in order to assure, that they do not play with the device.      
 
Precautionary Measures      
Care must be taken to ensure that during the course of the installation procedure no damage is caused by, 
for example, falling objects, sharp objects, walking on the surface-heating element or the like. The surface-
heating elements are to be powered by a circuit with a fault current breaker (F-1 Protection Switch) with a 
release current of 30 mA.  It is necessary to mount a warning notice in the close proximity of the distribution 
system which fully describes the lay-out of the heating unit. One of these plaques (about 105 x 148 mm) is 
required for each surface-heating element and the installer must enter the lay-out details of each surface-
heating element on the relevant plaque (a sketch will suffice). The heating cable must not be shortened or 
crossed  over  itself.  The  flooring  material  covering  the  surface-heating  element  should  have  the  least 
possible  resistance  to  the  conduction  of  heat.  Care  must  be  taken  to  ensure  that  the  surface-heating 
element  is  not  trodden  upon  while  the  floor  material  is  being  laid.  It  is  also  necessary  to  avoid  laying  the 
material  over  screed  expansion  joints.  Normal  practice  involves  using  a  control  thermostat  with  a  floor-
sensor, with the sensor inserted in an empty pipe. Please note that a defective sensor will not be replaced 
unless it was protected in this way. The sensor should be located close to the floor surface and between two 
lengths of heating cable. In the same way, the cold conductor (connecting cable) is also to be laid inside a 
separate  empty  pipe.  For  safety  reasons  a  switching  device  should  be  used  which  ensures  an  all-pole 
disconnection of this permanently fixed equipment.  This can be, for example, a 2-pole F1-Protective Switch 
(with a 3 mm gap).  
 
Laying Procedure  
The purpose of the
 
surface-heating elements is to provide direct heating and to achieve  control of floor 
surface temperatures. They must not be used for insertion in walls or ceilings. The individual loops of 
heating cable should run parallel to one another over the floor area and they should be separated by a 
minimum distance of 5 cm. The cold conductors (connection cables) must not cross over themselves. They 
are to run  alongside  and parallel to the surface-heating elements from the connection socket or directly to 
the thermostat. Several different surface-heating elements can be connected in parallel to one thermostat 
(in a similar manner to the connection of several light bulbs in a lighting fixture). In this situation we 
recommend the use of a connection socket. 
 