Vision Akkus VISION SOLAR-AKKU 12 V, 36 AH 6FM36DX Ficha De Dados

Códigos do produto
6FM36DX
Página de 1
6FM36D
12V 36Ah(20hr)
The rechargeable batteries are lead-lead dioxide systems. The dilute sulfuric acid electrolyte 
is absorbed by separators and plates and thus immobilized. Should the battery be 
accidentally overcharged producing hydrogen and oxygen, special one-way valves allow the 
gases to escape thus avoiding excessive pressure build-up. Otherwise, the battery is 
completely sealed and is, therefore, maintenance-free, leak proof and usable in any position. 
Battery Construction
Component
Positive plate
Negative plate
Container Cover Safety valve
Terminal
Separator
Electrolyte
Raw material
Lead dioxide
Lead
ABS
ABS
Rubber
Pb
Fiberglass
Sulfuric acid
General Features 
Absorbent Glass Mat (AGM) technology 
for efficient gas recombination of up to 
99% and freedom from electrolyte 
maintenance or water adding.
Not restricted for air transport-complies 
with IATA/ICAO Special Provision A67.
UL-recognized component.
Can be mounted in any orientation.
Computer designed lead, calcium tin alloy 
grid for high power density.
Long service life, float or cyclic 
applications.
Maintenance-free operation.
Low self discharge.
Dimensions and Weight
Length(mm / inch)
195 / 7.68
Width(mm / inch)
130 / 5.12
Height(mm / inch) 
155/ 6.10
Total Height(mm / inch) 
Approx. Weight(Kg / lbs) 
10.2 / 22.5 
Performance Characteristics 
Nominal Voltage
12V
Number of cell
6
Design Life 
10 years 
Nominal Capacity 77
o
F(25
o
C)
20 hour rate (1.8A, 10.5V)
36Ah
10 hour rate (3.6A, 10.5V)
34Ah
5 hour rate (6.1A, 10.5V)
30.5Ah
1 hour rate (36A, 9.6V)
25Ah
Internal Resistance
Fully Charged battery 77
o
F(25
o
C)
10mOhms
Self-Discharge
3% of capacity declined per month at 20
o
C(average)
Operating Temperature Range
Discharge
-20~60
o
C
Charge
-10~60
o
C
Storage
-20~60
o
C
Max. Discharge Current 77
o
F(25
o
C)
330A(5s)
Short Circuit Current
850A
Charge Methods: Constant Voltage Charge 77
o
F(25
o
C)
Cycle use
14.4-14.7V
        Maximum charging current
9.9A
        Temperature compensation 
-30mV/
o
C
Standby use 
13.6-13.8V
        Temperature compensation 
-20mV/
o
C
www.vision-batt.com
155 / 7.09
Cycle service life in relation to 
depth of discharge
Number of cycles(cycles)
Capacity(%)
120
100
80
60
40
20
0
200         400          600       800      1000     1200     1400     1600
100% D.O.D.
50% D.O.D.
30% Depth of discharge