ConiuGo 700100107 EasyGuard II 700100107 Manual Do Utilizador

Códigos do produto
700100107
Página de 54
 
16
 
Revision 9.0 
GSM Alarm & Telemetry systems 
#SIGNAL OK
 
Signal is higher then 8 and is good for the use of SMS services. 
 
#SIGNAL ERROR
 
The checking of the send quality reports a failure; maybee a  
hardware defect or defect antenna.
 
 
 
SIM-card-status 
Here the status of the used SIM- card will be reported.  
Possible answers: 
 
#NO SIMCARD 
No SIM card is in the unit. 
 
#PIN READY 
The PIN number which was entered is ok.  
 
#SIM PUK 
The SIM card needs a master PIN because the card is blocked 
 
#SIM PIN  
You have to enter the PIN number 
 
#SIM ERROR 
PIN number request sends an unknown error  
 
 
Modemstatus 
Shows the status of the internal GSM modem. Here will be shown possible 
restarts of the module or a reset of the modem. 
Possible answers: 
 
#RESET! 
The internal GSM modem will be resetted.  
 
#NEUSTART 
The modem will be switched on. 
 
#UNBEKANNT 
The internal modem is ready but is not tested right now.  
 
#OK 
 
The modem is ready.
 
 
 
ModemResetStatus  
This value is a count-down for the communication between the 
controller and the modem. The modem will be restarted at end of 
this procedure. However, the modem even during this modem reset 
registers incoming events and will reports them when the device is 
booked into the GSM network.