ConiuGo 700100107 EasyGuard II 700100107 Manual Do Utilizador
![ConiuGo](https://files.manualsbrain.com/attachments/0e59815d3cc86fbf1207c9ef5848af11d53c527e/common/fit/150/50/6387d12fce459b2b45e8c525987525a2cc9535b3f19d50960ea99566545f/brand_logo.gif)
Códigos do produto
700100107
53
Revision 9.0
GSM Alarm & Telemetry systems
D_IN
D1 + D2 < H
D 1 D 2
D 3
OUTC
H
OUTD
Duration "1"
D_IN
D1 + D2 < H
D 1 D 2
D 3
OUTC
H
H
OUTD
Duration "1"
D – duration of the impulse at digital input (at least 3 seconds)
H – pre-set hold time of the digital output (with a delay of some seconds)
Diagram 3
Function of the hold time of a digital input
The hold time of a digital input only has an effect to the falling edge of a negative
impulse. The edge increasing to "1" isn't influenced through the hold time.
At the parameter setting of the digital inputs a hold time is entered for an input
(shorter impulses are suppressed.)
Input impulse – External impulse, connected to input
D_IN –
Digital input with hold time
Input impulse
D_IN
H (obtained on the falling edge)