GSM Alarm & Telemetry systems 
Digital relay outputs 
The  digital  outputs  have  changeover  contacts  that  are  switched  by  an  event  pre-
defined  in  the  configuration  of  the  GSM  module.  Possible  applications  are  e.g.  si-
rens, visual signal (distress signals, etc.) but as well complex equipment like plants, 
machines, radiators. Regarding switched devices it has to be taken into account that 
they might be operated be by heavy current and so generally are not allowed not to 
be  switched  directly  by  the  module.  In  that  case  additional  components  are 
needed to switch the load (e.g. heavy current connecting relay etc.). 
The changeover contacts of the relay are named as follows: 
 
(“common") 
NC  
(“normally closed")  
[NO] 
(“normally open").  
 
Keep in mind these names to make a correct wiring of your application.  
 
With any digital output set to “1” the related crossover contacts close between  
C <> NO and opens the contacts C <> NC  
 
With any digital output set to “0” the related crossover contacts close between  
C <> NC and opens the contacts C <> NO  
 
 
 
The contacts under no condition are able to be switched to 
mains voltage. The maximum electrical load for the relay con-
tacts is 24 V, 1 A. 
 
 
6. Operation
 
 
The module has to be installed in dry indoor areas only; the acceptable temperature 
range is –30 °C to +60 °C. The general precautions  for the safe operation of electri-
cal equipment must be regarded.