Cep Terminals UMTS-TERMINAL HT910 G 6303 Ficha De Dados

Códigos do produto
6303
Página de 26
CEP AG
Revision 0.9
_________________________________________________________________________________
__________________________________________________________________________________________
Page 13 of 26
Large capacitors in your power supply which will lead to slow leading and
falling edges (issue does not apply with modern stabilized switching regulator
power-adaptors) AND TO_IN tied in parallel to VCC (instead of separate
dedicated digital signal)
Slow analogue signals used to assert TO_IN
TO_IN signal not before VCC
All 3 cases above might prevent the modem from recognizing the power-up signal
this is no failure of the modem itself, the same would apply to almost any electronic
device that provides a separate “power-on” or “reset” signal.
If you are doubt, please
Use the mains power adapter that is provided by your distributor and is know
to work properly with your modem
Make sure that your signal and system design is according to the above
Consult our support team that will be more than happy to assist you.
3.2 Switching OFF the modem
There are two ways to switch off (power down) the modem as described below:
use the AT#SHDN command; DTR permanently to low (0,8V)
HR_IN to high level for t > 5s
A delay of up to 10s is experienced as the modem logs off the network
3.3 Optional Low Power Mode
In addition to turning the device completely off the terminal can placed into a low power
mode while maintaining connectivity.  To put the device into this low power mode the DTR
line must be set to “low” and the AT command “at+cfun=5” must be issued.
In the low power mode current consumption is approximately 11mA with a 12V supply.
Current in normal standby mode is approximately 23mA at 12V
There is an additional optional “low power” variant that is available on a project bases that
can achieve 2mA with a 12V supply.
3.4 Operating states / LEDs