Texas Instruments Step Down Converter Bypass Mode Low Power Wireless Appl. Evaluation Module TPS62733EVM-726 TPS62733EVM-726 Ficha De Dados

Códigos do produto
TPS62733EVM-726
Página de 16
S001
Vout 2.1 V or 2.3 V
Test Summary
4.1
Equipment
Adjustable dc power supply between 1.8 V and 4 V with adjustable current limit set to approximately
150 mA
Load: system load or resistive load
21
Ω
Three Fluke 75 DMMs (equivalent or better)
Oscilloscope, model TDS222 (equivalent or better)
4.2
Equipment and EVM Setup
Table 1. Setup I/O Connections and Configuration for Evaluation of TPS62730, TPS62733 EVM
Jack and Component (Silk
Connect or Adjustment To:
Screen)
J1 (Vin)
Power supply positive lead, preset to 3.3 VDC, 150-mA current limit
J2-1 (+ SNS); input
Positive lead of DMM #1
J2-2 (- SNS); input
Negative lead of DMM #1
J3 (GND)
Power supply negative lead (3.3 VDC supply)
J4 (Vout)
Positive lead to system load or load resistance
J5-1 (+ SNS); output
Positive lead of DMM #2
J5-2 (- SNS); output
Negative lead of DMM #2
J6 (GND)
Negative lead to system load or load resistance
J7-1 (STAT)
Positive lead of DMM meter #3
J7-2 (GND)
Negative lead of DMM meter #3
JP1 (ON)
Apply shunt to ON (across pins 1 and 2) for converter operation
JP1 (Bypass)
Do not apply shunt to Bypass (across pins 2 and 3) until procedure calls for change.
Connect the meters, scope probes, output load, shunt, and input power supply as listed in
and set
the oscilloscope to 200 ns/div, positive trigger, dc-coupled on CH1, ac-coupled and 10 mV/div on CH2.
Use additional channels or move probes as required view Vin, Vstat and Vbypass. Replace the resistive
load with a system load or decade load box if desired to vary the load between 1 k
Ω
and 21
Ω
.
Figure 1. EVM Schematic and Evaluation Setup
3
SLVU455A – April 2011 – Revised August 2012
TPS62730, TPS62733 Stepdown Converters With Bypass Mode for Ultralow-
Power Wireless Applications
Copyright © 2011–2012, Texas Instruments Incorporated