Texas Instruments PCM9211EVM-U Evaluation Module PCM9211EVM-U PCM9211EVM-U Ficha De Dados

Códigos do produto
PCM9211EVM-U
Página de 27
www.ti.com
Dialogs and Active Objects
2.5.3 Register Inspector
The register inspector dialog (View->Register Inspector…) gives access to all registers of the TI audio
codec.
illustrates the register inspector dialog.
Figure 2-5. Register Inspector
The register inspector displays the content of the connected TI audio codec device registers. To trigger
reading the content of one page, click the Refresh button.
The addr column shows the address of the registers in decimal notation.
The description column contains a description for each register. If the register has no function
assigned, it is declared Reserved.
The data columns show the data of each register (one byte). The first data column uses decimal
notation, and the second uses hexadecimal notation. It is possible to change the register value by
clicking into one of the data fields and typing the new value (either decimal or hexadecimal).
The numbered columns show the register content in binary notation. Read/write bits are shown solid
black or red; read-only bits are gray or dark red. Red numbers represent bits that recently changed. To
change a single writable bit, click on the bit and it will flip.
The coefficients may be used for a specific customer filter implementation. The format is compatible with
the TI audio codec that was detected by the CodecControl software.
2.5.4 Script Syntax
A script is a text file that contains data to send to a device.
Each line in a script file is one command. No provision is made for extending lines beyond one line, except
for the > command. A line is terminated by a carriage return.
The first character of a line is the command. Commands are:
15
SBAU174 – June 2010
CodecControl Software
Copyright © 2010, Texas Instruments Incorporated