GUI Getting Started
6
GUI Getting Started
The I
2
C device address is set in the hardware for address 20h. The GUI also defaults to this address. If a
different address is needed, go to the GUI's right half of the screen's Setup Tab and enter the new I
2
C
address. See
Also in the Setup Tab screen, the 400-kHz I
2
C (default) is selected.
Leave the termination set to the default setting, open.
Figure 3. Interrupt/Events and Setup Tabs
Select the Configuration Tab (reference
). At the far right in the Configuration Screen, the
selections are global which means they apply to all 4 ports. At the pull down that says Manual, select
AUTO, and select the r0x12h Button just to the left of AUTO. The four columns to the left get set to
AUTO.
To the left of GLOBAL on this same screen the window allows individual set up for each output port.
Those selections are then applied using the r0x12h Button to the left of the four-port mode entries.
Detection and classification are initiated within the parameters of the mode already selected by either
global or single port selection in the same way the mode was set. Then click the r0x14h Button to
activate. Classification and detection can be set or cleared before initiation with the green CLEN and DEN
Rectangular Buttons 
The green LEDs turn on for good status indication.