Hellermann Tyton 402-16039 216-3-B8W 1 pc(s) Max 3.1 402-16039 Ficha De Dados

Códigos do produto
402-16039
Página de 1
Material
Polyolefin,
Chemically cross-linked (POX)
Colour
Black (BK)
Shrink Ratio
up to 3:1
Dielectric Strength
15 kV/mm
Minimum Shrink
Temperature
+135 °C
Operating 
Temperature
-55 °C to +80 °C 
Flammability
ASTM D635
Specification
Det Norske Veritas
HEV breakout boot
I n s u l a t i o n   P r o d u c t s
H e a t   S h r i n k a b l e   M o u l d e d   S h a p e s
301
2.2
Article-No.
Type
Recomm. application
(mm²)
min 
a
H
max
b
min 
a
J max
b
Recovered
from
to
P ± 10%  R ± 10% 
S nom
HW ± 20% 
JW ± 20% 
2 Finger Breakout Boot
402-16039
216-3-B8W
2.5
10.0
21.0
9.4
9.0
2.79
76.5
20.0
1.59
1.59
402-23058
223-2-B8W
4.0
35.0
33.0
9.4
17.5
4.1
94.0
30.0
20.0
1.5
1.2
402-18051
218-2-B8W
50.0
150.0
49.0
22.9
20.0
7.6
119.0
34.0
30.0
3.2
3.2
402-19032
219-2-B8W
185
400
87.0
38.1
43.0
12.7
141.5
42.5
44.0
3.8
3.8
3 Finger Breakout Boot
403-54004
354-1-B8W
16.0
45.0
45.0
10.0
16.0
4.0
100.0
25.0
3.0
2.0
403-20012
320-1-B8W
50.0
150.0
55.8
22.5
30.4
9.0
180.0
44.0
37.0
3.0
2.0
403-55005
355-1-B8W
150
240
100.0
28.0
40.0
13.0
210
50.0
3.5
2.5
403-24016
324-1-B8W
150
300.0
90.0
35.5
35.0
14.5
200.0
50.0
54.0
3.0
2.0
403-42006
342-1-B8W2
185
400
110.0
35.0
40.0
17.5
230.0
45.0
55.0
4.0
3.5
403-41005
341-1-B8W2
240
400.0
125.0
59.0
50.8
25.4
283.0
71.0
75.0
3.8
3.8
4 Finger Breakout Boot
404-42022
442-1-B8W
2.5
10.0
28.0
9.0
9.0
1.8
78.0
17.0
20.0
2.7
2.0
404-08022
408-2-B8W2
4.0
35.0
35.0
12.0
15.0
3.0
95.0
24.0
22.0
2.5
2.0
404-09021
409-2-B8W2
35.0
70.0
47.4
22.9
21.5
6.4
165.0
38.1
38.1
4.1
3.3
404-18020
418-4-B8W2
70.0
150.0
60.0
22.9
30.0
6.4
202.0
38.1
38.0
4.1
3.3
404-44010
444-1-B8W2
150
400.0
95.0
35.6
45.0
12.5
240.0
55.0
50.8
4.0
3.5
All Dimensions in mm, except for 
″mm²″. Subject to technical changes.
Please note! Not all products listed on
this page may have this approval. For
product specific approvals please refer to
the Appendix.
as supplied 
recovered
• HEV
Cable Break Out Boots for low
voltage applications, with and
without adhesive liner
Features and Benefits
Cable breakout boots are designed for
 insulating and sealing a cable crotch, or
conduit system, and provide excellent
 resistance to abrasion and weathering.
Application
Cable breakouts are manufactured from a
tough cross-linked polyolefin containing a
flame retardant. This allows the breakouts to
be used for both interior and exterior
 applications. They offer excellent electrical
and mechanical protection.
Cable breakouts are supplied with an  adhesive
inner coating for reliable environmental 
sealing, and are available for 2, 3, 4, 5 and 
6 core cables.
HEV breakout boot for two-core cable.
Technical Table

Material Data
Date of issue: April 2011