11. TECHNICAL DATA
NPI 150-12 NPI 150-24 NPI 300-12
NPI 300-24
NPI 500-12
Nominal input voltage
12V/DC
24V/DC
12V/DC
24V/DC
12V/DC
Input voltage range
11 – 15 V
22 – 30 V
11 – 15 V
22 – 30 V
11 – 15 V
Power consumption when idle
0.3A
0.3A
0.3A
0.3A
0.4A
max. input current
16A
8A
30A
15A
50A
Permanent output load
150 W
150 W
300 W
300 W
500 W
Peak output load
300 W
300 W
600 W
600 W
1000 W
Output voltage
230 V ± 5%
Output frequency
50 Hz ± 2
Operating temperature
-10 to +50°C
Storage temperature
-30 to +70°C
Degree of effectiveness
85%
Fuse
20A
10A
35A
20A
2 x 35A
Dimensions in mm:
170x90x62
170x90x62
190x90x62
190x90x62
250x90x62
Weight
0.9 kg
0.9 kg
1.2 kg
1.2 kg
1.4kg
NPI 500-24 NPI 1000-12 NPI 1000-24 NPI 2000-12 NPI 2000-24
Nominal input voltage
24V/DC
12V/DC
24V/DC
12V/DC
24V/DC
Input voltage range
22 – 30 V
11 – 15 V
22 – 30 V
11 – 15 V
22 – 30 V
Power consumption when idle
0.3A
0.4A
0.3A
0.6A
0.4A
max. input current
25A
108A
54A
211A
103A
Permanent output load
500 W
1000 W
1000 W
2000 W
2000 W
Peak output load
1000 W
2000 W
2000 W
4000 W
4000 W
Output voltage
230 V ± 5%
Output frequency
50 Hz ± 2
Operating temperature
-10 to +50°C
Storage temperature
-30 to +70°C
Degree of effectiveness
85%
Fuse
2 x 20A
internal
Dimensions in mm:
250x90x62
325x180x89 325x180x89 418x180x89 418x180x89
Weight
1.4 kg
3.0 kg
3.0 kg
4.5 kg
4.5 kg